SPONTANEOUSLY APPEARING MICROBUBBLES ASSOCIATED WITH PROSTHETIC CARDIAC VALVES DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY

被引:20
|
作者
ORSINELLI, DA [1 ]
PASIERSKI, TJ [1 ]
PEARSON, AC [1 ]
机构
[1] OHIO STATE UNIV,DEPT MED,DIV CARDIOL,COLUMBUS,OH 43210
关键词
D O I
10.1016/0002-8703(94)90599-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During transesophageal echocardiographic studies in patients with prosthetic cardiac valves, we have noticed the presence of bright, highly mobile echoes (termed microbubbles because of their similarity to saline contrast bubbles) that move rapidly away from the valve. These echoes are distinct from spontaneous echo contrast. The purpose of this study was to determine the frequency with which microbubbles are detected in association with prosthetic valves. No microbubbles were detected in association with bioprosthetic valves. Thus analysis was limited to 198 studies performed in 138 patients with left-sided mechanical valves. Microbubbles were detected in 69 (35%) studies. No differences were found between studies with and without microbubbles with regard to patient characteristics or the indication for the study. Among the 173 individual valves studied, microbubbles were more frequently detected in association with mitral valves (34 of 82, 41%) versus aortic valves (14 of 91, 15%; p 0.0001). Microbubbles were more frequently detected with disc-type mitral valves (30 of 42, 17%) in comparison to Starr-Edwards mitral valves (4 of 39, 10%; p 0.0001). Microbubbles were more often detected with abnormal valves (28 of 76, 37%) than normal valves (20 of 97, 21%), p 0.02. We conclude that bright, highly mobile echoes (microbubbles) distinct from spontaneous echo contrast are frequently detected during transesophageal echocardiography in association with mechanical prosthetic valves. Although the cause and clinical significance of these microbubbles are unknown, it is important to distinguish these echoes from valvular masses such as thrombus or vegetations.
引用
收藏
页码:990 / 996
页数:7
相关论文
共 50 条
  • [41] INVERTED LEFT ATRIAL APPENDAGE APPEARING AS A LEFT ATRIAL MASS WITH TRANSESOPHAGEAL ECHOCARDIOGRAPHY DURING CARDIAC-SURGERY
    ARONSON, S
    RUO, W
    SAND, M
    ANESTHESIOLOGY, 1992, 76 (06) : 1054 - 1055
  • [42] Iatrogenic Supravalvular Aortic Stenosis Detected by Transesophageal Echocardiography in a Pediatric Patient Undergoing Cardiac Surgery
    Lee, Ji-Hyun
    Nam, Karam
    Park, Yong-Hee
    Kim, Jin-Tae
    ANESTHESIA AND ANALGESIA, 2015, 120 (01): : 26 - 29
  • [43] REDUNDANT LOOPS OF CHORDAE TENDINEAE - A NEW POTENTIAL CARDIAC SOURCE OF EMBOLISM DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    ROTH, SL
    FRIEDMAN, GH
    BODENHEIMER, MM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A75 - A75
  • [44] Diagnostic accuracy of cardiac computed tomographic angiography and transesophageal echocardiography in evaluation of patients with prosthetic paravalvular leakage
    Hassan, Amr Youssef
    Kandil, Hossam Ibrahim
    Salem, Mohamed Ali
    Mohamed, Ahmed Shehata
    Kassem, Hussien Heshmat
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (08): : 1122 - 1130
  • [45] Real-Time Three-Dimensional Transesophageal Echocardiography in Valve Disease: Comparison With Surgical Findings and Evaluation of Prosthetic Valves
    Sugeng, Lissa
    Shernan, Stanton K.
    Weinert, Lynn
    Shook, Doug
    Raman, Jai
    Jeevanandam, Valluvan
    DuPont, Frank
    Fox, John
    Mor-Avi, Victor
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) : 1347 - 1354
  • [46] THE ROLE OF PROLONGED THROMBOLYTIC INFUSIONS AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THROMBOSED PROSTHETIC HEART-VALVES - CASE-REPORT AND REVIEW OF THE LITERATURE
    PULEO, JA
    FONTANET, HL
    SCHOCKEN, DD
    CLINICAL CARDIOLOGY, 1995, 18 (11) : 679 - 684
  • [47] Infections associated with prosthetic heart valves, vascular prostheses, and cardiac pacemakers and defibrillators
    Almirante, Benito
    Miro, Jose M.
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2008, 26 (10): : 647 - 664
  • [48] A scope on esophageal damage associated with routine transesophageal echocardiography use in cardiac surgery
    Abraham, Paul
    Siegenthaler, Nils
    Giraud, Raphael
    Bendjelid, Karim
    MINERVA ANESTESIOLOGICA, 2017, 83 (03) : 338 - 340
  • [49] ACCURACY OF DOPPLER ECHOCARDIOGRAPHY IN MEASURING CARDIAC-OUTPUT ACROSS PROSTHETIC HEART-VALVES INVIVO
    DITTMANN, H
    VOELKER, W
    SEIPEL, L
    CIRCULATION, 1987, 76 (04) : 529 - 529
  • [50] Unexpected, transesophageal echocardiography-detected left ventricular microbubbles during off-pump coronary artery bypass graft surgery
    Akhtar, S
    Lluberes, V
    Allen, K
    Rajaii-Khorasani, A
    Wasnick, JD
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (01) : 131 - 133