SPONTANEOUSLY APPEARING MICROBUBBLES ASSOCIATED WITH PROSTHETIC CARDIAC VALVES DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY

被引:20
|
作者
ORSINELLI, DA [1 ]
PASIERSKI, TJ [1 ]
PEARSON, AC [1 ]
机构
[1] OHIO STATE UNIV,DEPT MED,DIV CARDIOL,COLUMBUS,OH 43210
关键词
D O I
10.1016/0002-8703(94)90599-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During transesophageal echocardiographic studies in patients with prosthetic cardiac valves, we have noticed the presence of bright, highly mobile echoes (termed microbubbles because of their similarity to saline contrast bubbles) that move rapidly away from the valve. These echoes are distinct from spontaneous echo contrast. The purpose of this study was to determine the frequency with which microbubbles are detected in association with prosthetic valves. No microbubbles were detected in association with bioprosthetic valves. Thus analysis was limited to 198 studies performed in 138 patients with left-sided mechanical valves. Microbubbles were detected in 69 (35%) studies. No differences were found between studies with and without microbubbles with regard to patient characteristics or the indication for the study. Among the 173 individual valves studied, microbubbles were more frequently detected in association with mitral valves (34 of 82, 41%) versus aortic valves (14 of 91, 15%; p 0.0001). Microbubbles were more frequently detected with disc-type mitral valves (30 of 42, 17%) in comparison to Starr-Edwards mitral valves (4 of 39, 10%; p 0.0001). Microbubbles were more often detected with abnormal valves (28 of 76, 37%) than normal valves (20 of 97, 21%), p 0.02. We conclude that bright, highly mobile echoes (microbubbles) distinct from spontaneous echo contrast are frequently detected during transesophageal echocardiography in association with mechanical prosthetic valves. Although the cause and clinical significance of these microbubbles are unknown, it is important to distinguish these echoes from valvular masses such as thrombus or vegetations.
引用
收藏
页码:990 / 996
页数:7
相关论文
共 50 条
  • [1] Spontaneously appearing microbubbles associated with prosthetic mitral valves as assessed by transesophageal echocardiography and its clinical importance
    Ozkan, M
    Ozkan, M
    Kirma, C
    Enar, S
    Ozdemir, N
    Pektas, O
    CIRCULATION, 1997, 96 (08) : 1161 - 1161
  • [2] TRANSESOPHAGEAL ECHOCARDIOGRAPHY MICROBUBBLES WITH PROSTHETIC VALVES
    GLEN, SK
    WILSON, ES
    GROSSET, DG
    AMERICAN HEART JOURNAL, 1995, 130 (06) : 1312 - 1312
  • [3] Prevalence of microbubbles associated with mechanical prosthetic cardiac valves: A prospective transesophageal echocardiography study
    Gencbay, M
    Turan, F
    Yaymaci, B
    Degertekin, M
    Basaran, Y
    Dindar, I
    Izgi, A
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (03): : 340 - 344
  • [4] CHEMOPROPHYLAXIS BEFORE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH PROSTHETIC OR BIOPROSTHETIC CARDIAC VALVES
    GAL, RA
    GAECKLE, TC
    GADASALLI, S
    KUBOTA, JM
    ROBBINS, WG
    SCHMIDT, DH
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (01): : 115 - 117
  • [5] Echocardiography and doppler assessment of prosthetic heart valves with transesophageal echocardiography
    MacKenzie, GS
    Heinle, SK
    CRITICAL CARE CLINICS, 1996, 12 (02) : 383 - &
  • [6] TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE EVALUATION OF PROSTHETIC AND NATIVE AORTIC VALVES
    DITTRICH, HC
    MCCANN, HA
    WALSH, TP
    BLANCHARD, DG
    OPPENHEIM, GE
    WAACK, TC
    DONAGHEY, LB
    WHEELER, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (07): : 758 - 761
  • [7] Evaluation of Prosthetic Heart Valves by Transesophageal Echocardiography: Problems, Pitfalls, and Timing of Echocardiography
    Van den Brink, Renee B. A.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 10 (01) : 89 - 100
  • [8] Acute prosthetic valve dysfunction detected by intraoperative transesophageal echocardiography
    Shojima, T
    Hayashida, N
    Takagi, K
    Aoyagi, S
    JOURNAL OF CARDIOVASCULAR SURGERY, 2005, 46 (06): : 595 - 596
  • [9] EARLY DETECTION OF DYSFUNCTIONS OF PROSTHETIC HEART-VALVES BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    MOHRKAHALY, S
    ERBEL, R
    SZYDLOWSKY, D
    MEYER, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 55 - 55
  • [10] Prosthetic Valve Malfunction Caused by Chordal Entrapment Detected by Transesophageal Echocardiography
    Sawai, Toshiyuki
    Nakahira, Junko
    Shimoyama, Yuichiro
    Oka, Masayuki
    Imanaka, Hideaki
    Minami, Toshiaki
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 495 - 497