Endovascular treatment of a pulmonary artery pseudoaneurysm caused by Swan-Ganz catheter deployment in an anticoagulated patient

被引:2
|
作者
Ierardi, A. M. [1 ]
Xhepa, G. [1 ]
Musazzi, A. M. [2 ]
De Chiara, M. [1 ]
Beghi, C. [2 ]
Carrafiello, G. [1 ]
机构
[1] Insubria Univ, Dept Radiol, Intervent Radiol, Varese, Italy
[2] Insubria Univ, Dept Radiol, Cardiac Surg Dept, Varese, Italy
来源
BJR CASE REPORTS | 2015年 / 1卷 / 03期
关键词
D O I
10.1259/bjrcr.20150064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a case report of an anticoagulated 78-year-old male presenting with a pulmonary artery pseudoaneurysm following Swan-Ganz catheter deployment after an aortic valve and aortic root replacement. The diagnosis was established by cone-beam CT and catheter angiography, and embolization was achieved via a combination of plug and glue. This case emphasizes the importance of endovascular techniques in the management of iatrogenic pulmonary pseudoaneurysms and shows the benefit of using highly haemostatic polymeric agent in anticoagulated patients to obtain a rapid and effective occlusion.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] An emerging use of the Swan-Ganz catheter: Pulmonary artery catheter delivered thrombolysis in massive pulmonary embolism
    Jha, Abhishek
    Ahmed, Mohamed
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (03) : 728 - 729
  • [42] Rupture of pulmonary artery induced by Swan-Ganz catheter: Success of coil embolization
    Tayoro, J
    Dequin, PF
    Delhommais, A
    Alison, D
    Perrotin, D
    INTENSIVE CARE MEDICINE, 1997, 23 (02) : 198 - 200
  • [43] BANDING OF THE PULMONARY-ARTERY WITH AN INFLATED SWAN-GANZ CATHETER IN A PATIENT WITH POSTINFARCTION VENTRICULAR SEPTAL RUPTURE
    LOUWERENBURG, HW
    THIJSPLOKKER, HW
    ASCOOP, CAPL
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 16 (02): : 143 - 143
  • [44] RADIOLOGY OF SWAN-GANZ CATHETER AND ASSOCIATED PULMONARY COMPLICATIONS
    MCLOUD, TC
    PUTMAN, CE
    RADIOLOGY, 1975, 116 (01) : 19 - 22
  • [45] THE SWAN-GANZ CATHETER AND ITS APPLICATION IN THE GYNECOLOGIC PATIENT
    HELMKAMP, BF
    CIVETTA, JM
    GIRTANNER, R
    KREBS, HB
    POLIAKOFF, SR
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 139 (06) : 628 - 630
  • [46] CASES OF PULMONARY-ARTERY FALSE ANEURYSM INDUCED BY SWAN-GANZ CATHETER - TREATMENT BY EARLY EMBOLIZATION
    DURAND, M
    LAVAL, J
    FERRETTI, G
    PEREZ, I
    WOLLSCHLAGER, K
    BLIN, D
    GIRARDET, P
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 10 - 10
  • [47] COMPLETE HEART-BLOCK CAUSED BY THE SWAN-GANZ CATHETER
    MOSTBECK, G
    GASSNER, A
    SOMMER, G
    MINAR, E
    PICHLER, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 (11): : 700 - 703
  • [48] COMPLETE HEART-BLOCK CAUSED BY SWAN-GANZ CATHETER
    ABERNATHY, WS
    CHEST, 1974, 65 (03) : 349 - 349
  • [49] Thrombolytic Therapy of Acute Massive Pulmonary Embolism Using Swan-Ganz Pulmonary Artery Catheter
    Espina, Ilse
    Varon, Joseph
    Lin, Peter H.
    ANNALS OF VASCULAR SURGERY, 2017, 43 : 315.e9 - 315.e12
  • [50] Impact of using an indwelling introducer on diagnosis of swan-ganz pulmonary artery catheter colonization
    Valles, J
    Rello, J
    Matas, L
    Fontanals, D
    Baigorri, F
    Saura, P
    Artigas, A
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1996, 15 (01) : 71 - 75