INFLUENCES OF BAFFLES ON THE RATE OF HEAT-RECOVERY VIA A FINNED-TUBE HEAT-EXCHANGER IMMERSED IN A HOT-WATER STORE

被引:26
|
作者
CHAUVET, LP [1 ]
NEVRALA, DJ [1 ]
PROBERT, SD [1 ]
机构
[1] CRANFIELD INST TECHNOL,DEPT APPL ENERGY,CRANFIELD MK43 0AL,BEDS,ENGLAND
关键词
D O I
10.1016/0306-2619(93)90032-K
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The heat transfer at the external wall of the heat exchanger occurs primarily by buoyancy-driven natural convection in the surrounding water. An analysis of the effects of the presence of a rectangular duct on this heat-transfer process is presented. Small improvements in the rate of heat recovery were obtained repeatedly when a horizontal plate was located in the middle of the store.