DETERMINATION OF IMPURITIES IN HIGHLY PURIFIED HYDROFLUORIC-ACID BY ICP-MS

被引:0
|
作者
NAKAMURA, Y [1 ]
SIGEMORI, S [1 ]
TAKAHASHI, T [1 ]
TAKAKU, Y [1 ]
SIMAMURA, T [1 ]
机构
[1] MARUBUN CORP,CHUO KU,TOKYO 103,JAPAN
关键词
ICP-MS; DETERMINATION OF 34 IMPURITY ELEMENTS OF SUB PPB LEVEL; HIGHLY PURIFIED HYDROFLUORIC ACID;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination by ICP-MS of sub ppb level impurities in highly purified hydrofluoric acid has been investigated for routine analysis of factory products. Boron determination: mannitol of 4 mg was added to 100 g of the sample and the sample was evaporated to dryness on a water bath. The residue was dissolved by adding 1.2 ml of nitric acid (1 + 2). The final solution was made up to 10 ml with water and the boron content was determined by ICP-MS. Arsenic determination: nitric acid of 3 ml, saturated bromine water of 5 ml, and sulfuric acid (1 +99) of 1 ml were added to 90 g of the sample and the above procedures were repeated to determine arsenic content. Gold determination: 100 g of the sample was evaporated to dryness on a water bath, and the residue was dissolved by adding 0.4 ml of aqua regia. The sample was evaporated to dryness on a water bath again. This residue was again dissolved by adding 0.4 ml of aqua regia, and made up to 10 ml with water to determine Au. Niobium and Tantalum determination: The sample of 100 g was evaporated to dryness on a water bath and the residue was dissolved by adding 0.4 ml of hydrofluoric acid. The sample was made up to 10 ml with water to determine Ta and Nb. Determination of other impurities: The sample of 100 g (1000 g for the determination of Th and U) was evaporated to dryness on a water bath, and the residue was dissolved by adding 1.2 ml of nitric acid (1 + 2). The solution was made up to 10 ml with water to determine Li, Be, Na, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Co, Cu, Zn, Ga, Ge, Sr, Zr, Mo, Ag, Cd, Sn, Sb, Ba, Tl, Pb, Bi, Th and U. The recovery of each element was greater than about 90%. Analytical results of these impurities in highly purified hydrofluoric acid were sub ppb level concentration. The concentration of U and Th, were 0.03 ppt and 1 ppt, respectively.
引用
收藏
页码:T113 / T117
页数:5
相关论文
共 50 条
  • [31] Determination of age, isotopic ratios, and elemental impurities in nuclear materials by single quadrupole ICP-MS
    Serban, A.
    Albota, F.
    Ionuz, E.
    Tuta, C. S.
    Virgolici, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (01) : 165 - 173
  • [32] Determination of age, isotopic ratios, and elemental impurities in nuclear materials by single quadrupole ICP-MS
    A. Serban
    F. Albota
    E. Ionuz
    C. S. Tuta
    M. Virgolici
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 165 - 173
  • [33] Chloroformylation-Separation of Matrix and Determination of Trace Impurities in High Purity Chromium by ICP-MS
    Wang Jin-lei
    Qian Jun-min
    Li Bo
    Luo Lin
    Sun Bao-lian
    Xu Wei-jun
    Cui Ning
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (09) : 2896 - 2899
  • [34] Bromination-separation of Matrix and Determination of Sixteen Impurities in High Purity Tin by ICP-MS
    Wei Jian-Jun
    Lang Chun-Yan
    Lin Long-Fei
    Zheng Lin
    Li Jia-Xuan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (06) : 927 - 930
  • [35] Determination of Metallic Impurities by ICP-MS Technique in Eyeshadows Purchased in Poland. Part I
    Pawlaczyk, Aleksandra
    Gajek, Magdalena
    Balcerek, Martyna
    Szynkowska-Jozwik, Malgorzata, I
    MOLECULES, 2021, 26 (21):
  • [36] Behavior of the Pb-Li alloy impurities by ICP-MS
    Conde, E.
    Barrado, A. I.
    Pascual, L.
    Fernandez, M.
    Gomez de Salazar, J. M.
    Barrena, M. I.
    Quinones, J.
    FUSION ENGINEERING AND DESIGN, 2014, 89 (7-8) : 1246 - 1250
  • [37] Determination of trace impurities in tantalum pentoxide by ICP-AES and ICP-MS after trace-matrix-separation
    Opitz, M
    Wunsch, G
    JOURNAL FUR PRAKTISCHE CHEMIE-CHEMIKER-ZEITUNG, 1997, 339 (01): : 44 - 54
  • [39] ICP-MS Determination of Antimicrobial Metals in Microcapsules
    Rezic, Iva
    Skoc, Maja Somogyi
    Majdak, Mislav
    Juric, Slaven
    Stracenski, Katarina Sopko
    Vlahovicek-Kahlina, Kristina
    Vincekovic, Marko
    MOLECULES, 2022, 27 (10):
  • [40] Determination of neptunium in plutonium materials by ICP-MS
    Xu, N.
    Gallimore, D.
    Martinez, A.
    Townsend, L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 297 (01) : 127 - 132