AUTOMATED REAGENT STRIP URINALYSIS - UTILITY IN REDUCING WORK LOAD OF URINE MICROSCOPY AND CULTURE

被引:4
|
作者
TETRAULT, GA
机构
[1] Dept. of Pathology and Microbiology, Univ. of Nebraska Medical Center, Omaha, NE 68198-3135
关键词
D O I
10.1093/labmed/25.3.162
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This study correlated automated reagent strip results and urine micro-scopic findings, evaluated a screening protocol for use prior to microscopy, and determined whether urinalysis results could be used to reduce the frequency of negative urine cultures. Results from the reagent strip blood tests strongly correlated with the number of erythrocytes per high-power field. Reagent strip leukocyte esterase levels strongly correlated with the number of white blood cells per high-power field. A macroscopic screening protocol, using turbidity plus reagent strip protein, blood, and leukocyte esterase tests, detected more than 90% of urine specimens that contained abnormal formed elements. No combination of screening tests is effective in avoiding unnecessary urine culture when the cut point for a positive culture is 10,000 colony-forming units per milliliter of urine.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 38 条
  • [21] Use and quality of point-of-care microscopy, urine culture and susceptibility testing for urinalysis in general practice
    Kollerup, Ida
    Thomsen, Anne Kathrine Aagaard
    Kornum, Jette Brommann
    Paulsen, Kirsten Inger
    Bjerrum, Lars
    Hansen, Malene Plejdrup
    SCANDINAVIAN JOURNAL OF PRIMARY HEALTH CARE, 2022, 40 (01) : 3 - 10
  • [22] Urinalysis: Comparison between Microscopic Analysis and a New Automated Microscopy Image-Based Urine Sediment Instrument
    Bottini, Paula V.
    Martinez, Mayara H. M.
    Garlipp, Celia R.
    CLINICAL LABORATORY, 2014, 60 (04) : 693 - 697
  • [23] A CLINICAL LABORATORY EVALUATION OF A MULTI-REAGENT URINALYSIS TEST STRIP WITH LEUKOCYTE USING THE CLINITEK 10-URINE CHEMISTRY ANALYZER
    BROWN, S
    ERWINE, J
    WILLS, MR
    SAVORY, J
    KARMEN, A
    LENT, R
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1189 - 1189
  • [24] ELIMINATING UNNECESSARY URINE MICROSCOPY - RESULTS AND PERFORMANCE-CHARACTERISTICS OF AN ALGORITHM BASED ON CHEMICAL REAGENT STRIP TESTING
    WENZ, B
    LAMPASSO, JA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (01) : 78 - 81
  • [25] Extended nationwide evaluation of reagent test strip screening versus microscopy for detection of urine sediment abnormalities.
    Widran, SL
    Deindoerfer, FH
    CLINICAL CHEMISTRY, 1998, 44 : A160 - A160
  • [26] Utility of routine urinalysis and urine culture testing in an ambulatory urology clinic: a quality improvement initiative in a Veterans healthcare facility
    Richards, Kyle A.
    Cesario, Stacy
    Lim, Amy H.
    Best, Sara L.
    Deeren, Susan M.
    Bushman, Wade
    Safdar, Nasia
    CANADIAN JOURNAL OF UROLOGY, 2017, 24 (01) : 8627 - 8633
  • [27] Clinical laboratory automated urinalysis:: Comparison among automated microscopy, flow cytometry, two test strips analyzers, and manual microscopic examination of the urine sediments
    Mayo, S.
    Acevedo, D.
    Quinones-Torrelo, C.
    Canos, I.
    Sancho, M.
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2008, 22 (04) : 262 - 270
  • [28] A comparison of automated microscopy, urine dipstick and culture methods for diagnosing urinary tract infection
    Lunn, A.
    Watson, A. R.
    Holden, S.
    Boswell, T.
    PEDIATRIC NEPHROLOGY, 2008, 23 (09) : 1697 - 1697
  • [29] Utility of the urine reagent strip leucocyte esterase assay for the diagnosis of meningitis in resource-limited settings: meta-analysis
    Bortcosh, William
    Siedner, Mark
    Carroll, Ryan W.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2017, 22 (09) : 1072 - 1080
  • [30] Performance of urinalysis tests and their ability in predicting results of urine cultures: a comparison between automated test strip analyser and flow cytometry in various subpopulations and types of samples
    Yusuf, Erlangga
    Van Herendael, Bruno
    van Schaeren, Jef
    JOURNAL OF CLINICAL PATHOLOGY, 2017, 70 (07) : 631 - 636