ULTRA MICRO GLUTAMATE SENSOR USING PLATINIZED CARBON-FIBER ELECTRODE AND INTEGRATED COUNTER ELECTRODE

被引:17
|
作者
TAMIYA, E [1 ]
SUGIURA, Y [1 ]
TAKEUCHI, T [1 ]
SUZUKI, M [1 ]
KARUBE, I [1 ]
AKIYAMA, A [1 ]
机构
[1] TOKYO INST TECHNOL,GRAD SCH NAGATSUTA,MIDORI KU,YOKOHAMA,KANAGAWA 227,JAPAN
关键词
D O I
10.1016/0925-4005(93)87003-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An integrated ultra micro glutamate sensor has been constructed with a 7 mum diameter platinized carbon-fiber disk (PCD) electrode and a platinum thin-film (PTF) counter electrode fabricated on the glass capillary tube. By platinization, the electrode activity of the carbon fiber is improved. In order to obtain a stable response, a pulse potential is applied for hydrogen peroxide measurement. The PTF counter electrode shows good stability and can be used as a substitute for a silver-silver chloride electrode. Since the integrated PCD electrode shows good characteristics as a hydrogen peroxide sensor, glutamate oxidase is immobilized onto the tip of the PCD electrode to construct the ultra micro glutamate sensor. The sensor shows stable response to glutamate and a response time within 12 s. The calibration range for glutamate measurement is 50-800 muM.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 50 条
  • [31] Flow-through porous carbon-fiber electrode for electro-deposition
    Wang, Lixin
    Xi, Deli
    Hua, Tingting
    Li, Zhou
    Huagong Yejin/Engineering Chemistry & Metallurgy, 1997, 18 (02): : 102 - 107
  • [32] LIQUID-CHROMATOGRAPHY OF VITAMIN-B6 WITH ELECTROCHEMICAL DETECTION USING A CARBON-FIBER ELECTRODE
    HOU, WY
    JI, HM
    WANG, EK
    ANALYTICA CHIMICA ACTA, 1990, 230 (01) : 207 - 211
  • [33] BATTERIES AND ELECTRIC DOUBLE-LAYER CAPACITORS COMPOSED OF ACTIVATED CARBON-FIBER ELECTRODE
    MIKAWA, H
    NOGAMI, T
    YASHIMA, H
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1985, 121 (1-4): : 259 - 262
  • [34] DEVELOPMENT OF ACETYLCHOLINE SENSOR USING CARBON-FIBER (AMPEROMETRIC DETERMINATION)
    NAVERA, EN
    SODE, K
    TAMIYA, E
    KARUBE, I
    BIOSENSORS & BIOELECTRONICS, 1991, 6 (08): : 675 - 680
  • [35] ANODIC-OXIDATION OF HYDRAZINES AND THEIR METHYL-DERIVATIVES AT CARBON-FIBER ELECTRODE IN ACETONITRILE
    JANNAKOUDAKIS, AD
    THEODORIDOU, E
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-WIESBADEN, 1982, 129 (02): : 197 - 208
  • [36] MEASUREMENT OF PEROXIDE IN OILS BY CONTROLLED-POTENTIAL COULOMETRY USING A VAPOR-GROWN CARBON-FIBER ELECTRODE
    UCHIYAMA, S
    SHIMAMOTO, M
    SUZUKI, S
    HAMAMOTO, O
    ELECTROANALYSIS, 1990, 2 (03) : 259 - 261
  • [37] A NEW KIND OF FLOW-THROUGH ELECTROCHEMICAL DETECTOR USING CARBON-FIBER ELECTRODE FOR LIQUID-CHROMATOGRAPHY
    JI, HM
    HE, J
    WANG, ER
    DONG, SJ
    CHINESE SCIENCE BULLETIN, 1989, 34 (21): : 1842 - 1843
  • [38] Amperometric biosensing of glutamate using carbon nanotube based electrode
    Chakraborty, Sudip
    Raj, C. Retna
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (06) : 1323 - 1330
  • [39] Flexible Carbon-fiber Supported Carbon-sulfur Electrode: Preparation, Physical Property and Electrochemical Performance
    Li Ya-Dong
    Li Wei-Ping
    Wang Qin
    Zheng Dao-Guang
    Wang Jian-Xin
    JOURNAL OF INORGANIC MATERIALS, 2019, 34 (04) : 373 - 378
  • [40] A micro glucose sensor based on direct prototyping mesoporous carbon electrode
    Teng, Fei
    Wang, Xiaohong
    Shen, Caiwei
    Li, Siwei
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (06): : 1337 - 1343