EFFECT OF SPATIAL COHERENCE ON KNIFE-EDGE MEASUREMENTS OF DETECTOR MODULATION TRANSFER-FUNCTION

被引:5
|
作者
WERNICK, MN [1 ]
MORRIS, GM [1 ]
机构
[1] UNIV ROCHESTER, INST OPT, ROCHESTER, NY 14627 USA
来源
APPLIED OPTICS | 1994年 / 33卷 / 25期
关键词
MODULATION TRANSFER FUNCTION; PARTIAL COHERENCE EFFECTS; KNIFE-EDGE METHODS; CHARGE-COUPLED DEVICES;
D O I
10.1364/AO.33.005906
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
When an image of an edge object is used in the determination of the modulation transfer function of a detector array, the partial coherence of the illumination is often ignored. Although this approximation is valid in some cases, it may not be satisfactory, particularly for the small detector elements characteristic of present-day charge-coupled devices. Here we demonstrate the effect of partial coherence on edge-based modulation transfer function determination for various pixel,sizes, degrees of coherence, and f-numbers of the test optics.
引用
收藏
页码:5906 / 5913
页数:8
相关论文
共 50 条
  • [41] MODULATION TRANSFER-FUNCTION AND THICKNESS OF CUT
    AMTEY, SR
    READ, ME
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (04): : 591 - 591
  • [42] MODULATION TRANSFER-FUNCTION OF TURBID WATER
    KONDO, K
    MATSUI, T
    MIURA, S
    OKAMOTO, H
    JOURNAL OF THE RADIO RESEARCH LABORATORY, 1975, 22 (109): : 81 - 94
  • [43] Exact Reconstruction of THz Sub-λ Source Features in Knife-Edge Measurements
    Peccianti, Marco
    Clerici, Matteo
    Pasquazi, Alessia
    Caspani, Lucia
    Ho, Sze Phing
    Buccheri, Fabrizio
    Ali, Jalil
    Busacca, Alessandro
    Ozaki, Tsuneyuki
    Morandotti, Roberto
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2013, 19 (01) : 97 - 107
  • [44] EFFECT OF SOURCE TEMPORAL COHERENCE ON OPTICAL TRANSFER-FUNCTION IN WEAK TURBULENCE
    YANG, CC
    PLONUS, MA
    APPLIED OPTICS, 1994, 33 (09): : 1771 - 1775
  • [45] MODELING THE IMAGES OF KNIFE-EDGE EXPOSURES AND MACRO CONTRAST OF DIFFUSION TRANSFER MATERIALS
    FYSON, JR
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1990, 38 (4-5): : 130 - 134
  • [47] CHOICE OF CLIP LEVELS FOR BEAM WIDTH MEASUREMENTS USING KNIFE-EDGE TECHNIQUES
    SIEGMAN, AE
    SASNETT, MW
    JOHNSTON, TF
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1991, 27 (04) : 1098 - 1104
  • [48] COMPARISON BETWEEN MODULATION TRANSFER-FUNCTION AND CONTRAST SENSITIVITY MEASUREMENTS ON HUMAN EYES
    MAGNANTE, PC
    MILLER, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1281 - 1281
  • [49] INFLUENCE OF SIZE OF TEST FIELD EMPLOYED IN MEASUREMENTS OF MODULATION TRANSFER-FUNCTION OF EYE
    SIMON, JF
    DENIEUL, PM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1973, 63 (07) : 894 - 896
  • [50] MEASUREMENTS OF STELLAR SPECKLE INTERFEROMETRY LENS-ATMOSPHERE MODULATION TRANSFER-FUNCTION
    AIME, C
    KADIRI, S
    RICORT, G
    RODDIER, C
    VERNIN, J
    OPTICA ACTA, 1979, 26 (05): : 575 - 581