Infective endocarditis following coil occlusion of perimembranous ventricular septal defect with the Nit-Occlud (R) Le device

被引:7
|
作者
El-Sisi, Amal M. [1 ]
Menaissy, Yasser M. [2 ]
Bekheet, Samia A. [1 ]
机构
[1] Cairo Univ, Dept Paediat, Cairo, Egypt
[2] Cairo Univ, Dept Cardiothorac, Cairo, Egypt
关键词
Infective endocarditis; PFM coil; ventricular septal defect;
D O I
10.4103/0974-2069.171355
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Nitinol coil system was recently developed by "PFM" specifically for the transcatheter occlusion of ventricular septal defects (VSD). The device consists of a coil fitted with polyester fibers designated for the closure of perimembranous defects with an aneurysmal septum and some muscular VSDs. We report a case of fatal acute infective endocarditis 10 days following the procedure.
引用
收藏
页码:59 / 61
页数:3
相关论文
共 34 条
  • [21] Results and cost analysis of Amplatzer® Ductal Occluder-ii, Nit Occlud® Le Coil, and Konar-MF® ventricular septal defect occluder for percutaneous ventricular septal defect closure
    Gunawijaya, Eka
    Yantie, Ni Putu Veny Kartika
    Gunawijaya, Anlidya Permatasari
    BALI MEDICAL JOURNAL, 2023, 12 (01) : 1054 - 1058
  • [22] Infective aortic valve endocarditis in a cat with patent ductus arteriosus and perimembranous ventricular septal defect
    Brennan, C.
    Gunasekaran, T.
    Williams, K.
    Sanders, R. A.
    JOURNAL OF VETERINARY CARDIOLOGY, 2020, 31 : 30 - 35
  • [23] Percutaneous Device Occlusion and Minimally Invasive Surgical Repair for Perimembranous Ventricular Septal Defect
    Chen, Zhao Yang
    Lin, Bing Ru
    Chen, Wan Hua
    Chen, Qiang
    Guo, Xiu Fen
    Chen, Liang-Long
    Ge, Jun Bo
    ANNALS OF THORACIC SURGERY, 2014, 97 (04): : 1400 - 1406
  • [24] Perimembranous ventricular septal defect vegetation in a patient with right- and left-sided infective endocarditis
    Jorge, Claudia
    Marques, Joao Silva
    Nobre, Angelo
    Correia, Maria Jose
    Diogo, Antonio Nunes
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (11) : 951 - 952
  • [25] Multicenter nit-occlud® PDA-R patent. Ductus arteriosus occlusion device trial: Initial and six-month results
    Granja, Miguel A.
    Trentacoste, Luis
    Rivarola, Marcelo
    Barbosa, Jesus Damsky
    Lucini, Victorio
    Peirone, Alejandro
    Spillman, Ana
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (02) : 258 - 263
  • [26] Dislocation of an Amplatzer device occluder 12 years following transcatheter insertion for a perimembranous ventricular septal defect
    Song, Lingyun
    An, Qi
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (12) : 867 - 869
  • [27] Comparison of Effectiveness and Cost Between Perventricular Device Occlusion and Minimally Invasive Surgical Repair for Perimembranous Ventricular Septal Defect
    Yu Kun Luo
    Wan Hua Chen
    Chang Xiong
    Chuan Chuan Li
    Liang Long Chen
    Pediatric Cardiology, 2015, 36 : 308 - 313
  • [28] Comparison of Effectiveness and Cost Between Perventricular Device Occlusion and Minimally Invasive Surgical Repair for Perimembranous Ventricular Septal Defect
    Luo, Yu Kun
    Chen, Wan Hua
    Xiong, Chang
    Li, Chuan Chuan
    Chen, Liang Long
    PEDIATRIC CARDIOLOGY, 2015, 36 (02) : 308 - 313
  • [29] INFECTIVE ENDOCARDITIS FOLLOWING PATCH CLOSURE OF VENTRICULAR SEPTAL-DEFECT - A CROSS-SECTIONAL DOPPLER ECHOCARDIOGRAPHIC STUDY
    SHRIVASTAVA, S
    RADHAKRISHNAN, S
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1989, 25 (01) : 27 - 31
  • [30] Very late-onset endocarditis complicated by non-significant aortic regurgitation after device closure of perimembranous ventricular septal defect
    Tang, Changqing
    Zhou, Kaiyu
    Hua, Yimin
    Wang, Chuan
    MEDICINE, 2020, 99 (19) : E20120