HOT-ELECTRON MICROCALORIMETERS FOR X-RAY AND PHONON DETECTION

被引:26
|
作者
NAHUM, M [1 ]
MARTINIS, JM [1 ]
CASTLES, S [1 ]
机构
[1] NASA,GODDARD SPACE FLIGHT CTR,GREENBELT,MD 20771
关键词
D O I
10.1007/BF00693504
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a novel hot-electron microcalorimeter for measurements of x-rays or phonons produced by the interaction of a high energy particle with the underlying substrate. This type of detector uses a normal metal film to absorb the incoming excitation which subsequently heats the electrons above the lattice temperature. The temperature of the electrons is measured from the current - voltage characteristics of a superconductor-insulator-normal metal tunnel junction, where part of the absorber forms the normal electrode. We present simple calculations of the energy sensitivity of the junction and of the ultimate performance of x-ray and phonon detectors. We also present preliminary measurements of prototype devices which were used to test the basic detector physics.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 50 条
  • [1] Performance of hot-electron bolometers for infrared and X-ray detection
    Mels, WA
    Bruijn, MP
    Hoevers, HFC
    Frericks, M
    Kiewiet, FB
    Bento, AC
    de Korte, PAJ
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 255 - 265
  • [2] HOT-ELECTRON MICROCALORIMETERS AS HIGH-RESOLUTION X-RAY-DETECTORS
    NAHUM, M
    MARTINIS, JM
    APPLIED PHYSICS LETTERS, 1995, 66 (23) : 3203 - 3205
  • [3] Electron-phonon multiplier involving a cascade of NIS tunnel junctions and hot-electron microcalorimeters
    Shpinel, VS
    PHYSICS OF ATOMIC NUCLEI, 2002, 65 (01) : 38 - 40
  • [4] Electron-phonon multiplier involving a cascade of NIS tunnel junctions and hot-electron microcalorimeters
    V. S. Shpinel
    Physics of Atomic Nuclei, 2002, 65 : 38 - 40
  • [5] X-RAY DIAGNOSTIC FOR MEASUREMENT OF HOT-ELECTRON POWER LOSS
    RESS, D
    RICE, BW
    HORTON, RD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2777 - 2779
  • [7] A hot-electron microcalorimeter for X-ray detection using a superconducting transition edge sensor with electrothermal feedback
    Natl. Inst. of Std. and Technology, Boulder, CO 8303, United States
    不详
    Nucl Instrum Methods Phys Res Sect A, 1 (177-179):
  • [8] A hot-electron microcalorimeter for X-ray detection using a superconducting transition edge sensor with electrothermal feedback
    Irwin, KD
    Hilton, GC
    Martinis, JM
    Cabrera, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01): : 177 - 179
  • [9] MICROCALORIMETERS FOR X-RAY SPECTROSCOPY
    SILVER, E
    HAILEY, C
    LABOV, S
    MADDEN, N
    LANDIS, D
    GOULDING, F
    CHANAN, B
    RUTLEDGE, J
    BERNSTEIN, G
    RICHARDS, P
    KAHN, S
    BECKER, R
    JOURNAL DE PHYSIQUE, 1988, 49 (C-1): : 41 - 41
  • [10] X-ray microanalysis with microcalorimeters
    Isaila, C
    von Feilitzsch, F
    Höhne, J
    Hollerith, C
    Phelan, K
    Simmnacher, B
    Weiland, R
    Wernicke, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 734 - 736