Athermalization and Narcissus Analysis of Mid-IR Dual-FOV IR Optics

被引:0
|
作者
Jeong, Do Hwan [1 ]
Lee, Jun Ho [1 ]
Jeong, Ho [2 ]
Ok, Chang Min [2 ]
Park, Hyun-Woo [2 ]
机构
[1] Kongju Natl Univ, Dept Opt Engn, 1223-24 Cheonan Daero, Cheonan 31080, South Korea
[2] LIG Nex1 Co Ltd, 207 Mabuk Ro, Yongin 16911, South Korea
关键词
Infrared optics; Lens design; Narcissus; Athermalization;
D O I
10.3807/KJOP.2018.29.3.110
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have designed a mid-infrared optical system for an airborne electro-optical targeting system. The mid-IR optical system is a dual-field-of-view (FOV) optics for an airborne electro-optical targeting system. The optics consists of a beam-reducer, a zoom lens group, a relay lens group, a cold stop conjugation optics, and an IR detector. The IR detector is an f/5.3 cooled detector with a resolution of 1280 x 1024 square pixels, with a pixel size of 15 x 15 mu m. The optics provides two stepwise FOVs (1.50 degrees x 1.20 degrees and 5.40 degrees x 4.32 degrees) by the insertion of two lenses into the zoom lens group. The IR optical system was designed in such a way that the working f-number (f/5.3) of the cold stop internally provided by the IR detector is maintained over the entire FOV when changing the zoom. We performed two analyses to investigate thermal effects on the image quality: athermalization analysis and Narcissus analysis. Athermalization analysis investigated the image focus shift and residual high-order wavefront aberrations as the working temperature changes from -55 degrees C to 50 degrees C. We first identified the best compensator for the thermal focus drift, using the Zernike polynomial decomposition method. With the selected compensator, the optics was shown to maintain the on-axis MTF at the Nyquist frequency of the detector over 10%, throughout the temperature range. Narcissus analysis investigated the existence of the thermal ghost images of the cold detector formed by the optics itself, which is quantified by the Narcissus Induced Temperature Difference (NITD). The reported design was shown to have an NITD of less than 1.5 degrees C.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [21] Mid-IR Colloidal Nanocrystals
    Lhuillier, E.
    Keuleyan, S.
    Liu, H.
    Guyot-Sionnest, P.
    CHEMISTRY OF MATERIALS, 2013, 25 (08) : 1272 - 1282
  • [22] Mid-IR optoacoustic microscopy
    Rita Strack
    Nature Methods, 2020, 17 : 251 - 251
  • [23] Advances in Mid-IR Materials
    Schunemann, Peter G.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1195 - 1196
  • [24] Mid-IR optoacoustic microscopy
    Strack, Rita
    NATURE METHODS, 2020, 17 (03) : 251 - 251
  • [25] Mid-IR ectrosco Sensing
    Picqué N.
    Hänsch T.W.
    Optics and Photonics News, 2019, 30 (06): : 26 - 33
  • [26] Mid-IR Silicon Photonics
    Mashanovich, Goran Z.
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 789 - 789
  • [27] Performance Evaluation of Mid-IR Spectrometers by Using a Mid-IR Tunable Optical Parametric Oscillator
    Nam, Hee Jin
    Bae, In-Ho
    Kim, Seung Kwan
    Choi, Young-Jun
    Ko, Jae-Hyeon
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2019, 30 (04) : 154 - 158
  • [28] Optimization of mid-IR Photothermal Imaging for Tissue Analysis
    Totachawattana, Atcha
    Erramilli, Shyamsunder
    Sander, Michelle Y.
    ULTRAFAST NONLINEAR IMAGING AND SPECTROSCOPY III, 2015, 9584
  • [29] Spectral Analysis of Mid-IR Excesses of White Dwarfs
    Bilikova, Jana
    Chu, You-Hua
    Su, Kate
    Gruendl, Robert A.
    Rauch, Thomas
    PLANETARY SYSTEMS BEYOND THE MAIN SEQUENCE, 2011, 1331 : 215 - +
  • [30] Mid-IR photothermal sensing of liquids for trace analysis
    Ricchiuti, Giovanna
    Dabrowska, Alicja
    Pinto, Davide
    Ramer, Georg
    Lendl, Bernhard
    PHOTONIC INSTRUMENTATION ENGINEERING X, 2023, 12428