ARTIFACTS CAUSED BY DENTAL FILLING MATERIALS IN MR-IMAGING

被引:0
|
作者
VIKHOFF, B
RIBBELIN, S
KOHLER, B
EKHOLM, S
BORRMAN, H
机构
[1] SAHLGRENS UNIV HOSP, DEPT RADIAT PHYS, GOTHENBURG, SWEDEN
[2] SAHLGRENS UNIV HOSP, DEPT DIAGNOST RADIOL, GOTHENBURG, SWEDEN
[3] GOTHENBURG UNIV, FAC ODONTOL, DEPT DENT TECHNOL, GOTHENBURG, SWEDEN
[4] GOTHENBURG UNIV, FAC ODONTOL, DEPT ORAL PATHOL, FORENS ODONTOL SECT, GOTHENBURG, SWEDEN
关键词
MR IMAGING; DENTAL MATERIALS; ARTIFACTS; EXPERIMENTAL;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An investigation regarding possible artefacts from dental filling materials in MR imaging is presented including 9 types of such materials from various manufacturers. Freshly extracted teeth were prepared and the filling materials were handled according to manufacturers' instructions. The teeth were encapsulated into a gel phantom based on de-ionized water, Ni (NO3)(2) and polysaccharide agarose powder. The investigation was performed with a standard head coil and a 1.5 T MR unit. Images acquired with various combinations of parameters from different sequences were visually analysed regarding possible artefacts. The investigation showed that only one of the materials caused significant artefacts. The gel phantom was found to be a valuable means for examination of artefacts from small samples, and can be recommended as a standard technique for this purpose.
引用
收藏
页码:323 / 325
页数:3
相关论文
共 50 条
  • [21] MR OF BALLISTIC MATERIALS - IMAGING ARTIFACTS AND POTENTIAL HAZARDS
    SMITH, AS
    HURST, GC
    DUERK, JL
    DIAZ, PJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (03) : 567 - 572
  • [22] MR-IMAGING OF THE RETROPERITONEUM
    BARKER, CD
    BROWN, JJ
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (02) : 102 - 111
  • [23] MR-IMAGING OF THE GLOBE
    MAFEE, MF
    ECANOW, JS
    ECANOW, DB
    PARA, PF
    RADIOLOGY, 1995, 197 : 488 - 488
  • [24] INTERVENTIONAL MR-IMAGING
    ANZAI, Y
    DESALLES, AAF
    BLACK, KL
    SINHA, S
    FARAHANI, K
    BEHNKE, EA
    CASTRO, DJ
    LUFKIN, RB
    RADIOGRAPHICS, 1993, 13 (04) : 897 - 904
  • [25] INTERVENTIONAL MR-IMAGING
    LUFKIN, RB
    RADIOLOGY, 1995, 197 (01) : 16 - 18
  • [26] MR-IMAGING OF THYMOLIPOMA
    MATSUDAIRA, N
    HIRANO, H
    ITOU, S
    MATSUURA, K
    KANOU, M
    OGAWA, T
    MAGNETIC RESONANCE IMAGING, 1994, 12 (06) : 959 - 961
  • [27] MR-IMAGING OF THE BREAST
    WEINREB, JC
    NEWSTEAD, G
    RADIOLOGY, 1995, 196 (03) : 593 - 610
  • [28] MR-IMAGING OF THE PANCREAS
    SEMELKA, RC
    ASCHER, SM
    RADIOLOGY, 1993, 188 (03) : 593 - 602
  • [29] Developments in MR-imaging
    Knake, S.
    EPILEPSIA, 2007, 48 : 17 - 17
  • [30] Artifacts in MR imaging caused by small quantities of powdered iron
    Alanen, A., 1600, Munksgaard Int Publ. Ltd., Copenhagen K,, Denmark (36):