USE OF CINE GRADIENT-ECHO (GRE) MR IN THE IMAGING OF CARDIAC HEMOCHROMATOSIS

被引:13
|
作者
BLANKENBERG, F
EISENBERG, S
SCHEINMAN, MN
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO MED CTR,DEPT RADIOL,SAN FRANCISCO,CA
[2] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO MED CTR,DIV CARDIOL,SAN FRANCISCO,CA
关键词
HEART; DISEASES; HEMOCHROMATOSIS; MAGNETIC RESONANCE IMAGING; TECHNIQUES;
D O I
10.1097/00004728-199401000-00029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This case report describes the MR appearance of cardiac iron deposition using spin echo and cine gradient echo imaging (GRE) in a young man with secondary hemochromatosis. The ratio of the signal intensity of left ventricular myocardium to skeletal muscle was abnormally low on both spin echo and GRE compared with normal. The abnormally low myocardial signal was most severe on the cine gradient echo sequence. Cine GRE can be used to establish the diagnosis of cardiac iron deposition.
引用
下载
收藏
页码:136 / 138
页数:3
相关论文
共 50 条
  • [21] MR-IMAGING OF THE BRAIN - COMPARISON OF GRADIENT-ECHO AND SPIN-ECHO PULSE SEQUENCES
    PUI, MH
    FOK, ECM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 959 - 962
  • [22] LEFT-VENTRICULAR THROMBI - EVALUATION WITH SPIN-ECHO AND GRADIENT-ECHO MR IMAGING
    JUNGEHULSING, M
    SECHTEM, U
    THEISSEN, P
    HILGER, HH
    SCHICHA, H
    RADIOLOGY, 1992, 182 (01) : 225 - 229
  • [23] OPTIMIZATION OF GRADIENT-ECHO MR FOR CALCIUM DETECTION
    HENKELMAN, M
    KUCHARCZYK, W
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (03) : 465 - 472
  • [24] ACUTE HYPERTENSIVE ENCEPHALOPATHY - FINDINGS ON SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING
    WEINGARTEN, K
    BARBUT, D
    FILIPPI, C
    ZIMMERMAN, RD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 665 - 670
  • [25] MAGNETIZATION-PREPARED CARDIAC IMAGING USING GRADIENT-ECHO ACQUISITION
    LIU, Y
    RIEDERER, SJ
    EHMAN, RL
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 271 - 275
  • [26] CINE GRADIENT REFOCUSED ECHO (GRE) IMAGING OF INTRAVASCULAR MASSES - DIFFERENTIATION BETWEEN TUMOR AND NONTUMOR THROMBUS
    SEELOS, KC
    CAPUTO, GR
    CARROL, CL
    HRICAK, H
    HIGGINS, CB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (02) : 169 - 175
  • [27] QUANTITATION OF STRUCTURAL DISTORTION OF THE CERVICAL NEURAL FORAMINA IN GRADIENT-ECHO MR IMAGING
    TIEN, RD
    BUXTON, RB
    SCHWAIGHOFER, BW
    CHU, PK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 683 - 687
  • [28] DEEP VENOUS THROMBOSIS - EXPERIENCE WITH GRADIENT-ECHO MR IMAGING IN 66 PATIENTS
    SPRITZER, CE
    SOSTMAN, HD
    WILKES, DC
    COLEMAN, RE
    RADIOLOGY, 1990, 177 (01) : 235 - 241
  • [29] MR TOMOGRAPHY VIA GRADIENT-ECHO IMAGING IN CARDIOVASCULAR-DISEASES AND ANOMALIES
    DULCE, MC
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (04): : 285 - 293
  • [30] Xanthogranulomatous cholecystitis: importance of chemical-shift gradient-echo MR imaging
    Masamitsu Hatakenaka
    Toshisada Adachi
    Ayumi Matsuyama
    Masaki Mori
    Yasuji Yoshikawa
    European Radiology, 2003, 13 : 2233 - 2235