SUITABILITY OF POLYSTYRENE FOR VOLTAMMETRIC CELLS - A DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRIC STUDY

被引:14
|
作者
DIAZCRUZ, S [1 ]
DIAZCRUZ, JM [1 ]
ESTEBAN, M [1 ]
机构
[1] UNIV BARCELONA,DEPT ANALYT CHEM,E-08028 BARCELONA,SPAIN
关键词
D O I
10.1021/ac00081a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The convenience of using polystyrene as material for voltammetric cells in the determination of Zn, Cd, Pb, and Cu was studied by differential pulse anodic stripping voltammetry. Cells of glass, PTFE Teflon, colorless polystyrene, and white polystyrene were compared. Polystyrene seems to be more suitable than PTFE Teflon or glass, especially at pH > 6, in 0.01 mol L(-1) KNO3 medium. In 0.5 mol L(-1) NaCl medium, differences between PTFE Teflon and polystyrene are not so important. However, the, use of polystyrene cells seems especially appropriate for measurements of Pb(II) and Cu(II).
引用
收藏
页码:1548 / 1551
页数:4
相关论文
共 50 条
  • [1] Differential pulse anodic stripping voltammetric determination of endosulfan
    Mathew, L
    Reddy, MLP
    Rao, TP
    Iyer, CSP
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1998, 37 (11): : 1027 - 1028
  • [2] DETERMINATION OF LEAD IN PAINT BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    LAI, PC
    FUNG, KW
    [J]. ANALYST, 1978, 103 (1233) : 1244 - 1248
  • [3] Differential-pulse adsorptive stripping voltammetric determination of the antibacterial lomefloxacin
    Vílchez, JL
    Araujo, L
    Prieto, A
    Navalón, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (01) : 23 - 29
  • [4] A DIRECT DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRIC METHOD FOR THE DETERMINATION OF THALLIUM IN NATURAL-WATERS
    BONELLI, JE
    TAYLOR, HE
    SKOGERBOE, RK
    [J]. ANALYTICA CHIMICA ACTA, 1980, 118 (02) : 243 - 256
  • [5] RESOLUTION OF HIGHLY OVERLAPPED DIFFERENTIAL PULSE POLAROGRAPHIC AND ANODIC-STRIPPING VOLTAMMETRIC PEAKS BY MULTICOMPONENT ANALYSIS
    TURNES, G
    CLADERA, A
    GOMEZ, E
    ESTELA, JM
    CERDA, V
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 338 (1-2): : 49 - 60
  • [6] ALGAE COLUMNS WITH ANODIC-STRIPPING VOLTAMMETRIC DETECTION
    KUBIAK, WW
    WANG, J
    DARNALL, D
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (05) : 468 - 471
  • [7] DETERMINATION OF LEAD AND CADMIUM IN URINE BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    ONAR, AN
    TEMIZER, A
    [J]. ANALYST, 1987, 112 (03) : 227 - 229
  • [8] RAPID DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRIC METHOD FOR THE DETERMINATION OF BISMUTH IN BLOOD-SERUM AND URINE
    BANTJES, NV
    HAMILTON, DW
    [J]. SOUTH AFRICAN JOURNAL OF CHEMISTRY, 1985, 38 (01) : 21 - 24
  • [9] DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF TRACES OF LEAD IN HIGH-PURITY COPPER AFTER ITS SEPARATION BY ION-EXCHANGE
    KAYASTH, SR
    BASU, AK
    CHATTOPADHYAY, N
    DESAI, HB
    [J]. ANALYTICA CHIMICA ACTA, 1990, 231 (01) : 133 - 136
  • [10] ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF ANTIMONY IN GUNSHOT RESIDUE
    BRINER, RC
    CHOUCHOIY, S
    WEBSTER, RW
    POPHAM, RE
    [J]. ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) : 31 - 37