INVITRO AND INVIVO STABILITY OF ELECTRODE-POTENTIALS IN NEEDLE-TYPE GLUCOSE SENSORS - INFLUENCE OF NEEDLE MATERIAL

被引:19
|
作者
VELHO, G
FROGUEL, P
STERNBERG, R
THEVENOT, DR
REACH, G
机构
[1] HOTEL DIEU,SERV DIABET,1 PL PARVIS NOTRE DAME,F-75181 PARIS 04,FRANCE
[2] UNIV PARIS 12,BIOELECTROCHIM & ANAL MILIEU,F-94010 CRETEIL,FRANCE
关键词
D O I
10.2337/diabetes.38.2.164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:164 / 171
页数:8
相关论文
共 50 条
  • [31] BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR WITH POTENTIAL FOR USE IN-VIVO
    CHEN, CY
    SU, YC
    ISHIHARA, K
    NAKABAYASHI, N
    TAMIYA, E
    KARUBE, I
    ELECTROANALYSIS, 1993, 5 (04) : 269 - 276
  • [32] DIRECT MEASUREMENT OF WHOLE-BLOOD GLUCOSE BY A NEEDLE-TYPE SENSOR
    YAMASAKI, Y
    UEDA, N
    NAO, K
    SEKIYA, M
    KAWAMORI, R
    SHICHIRI, M
    KAMADA, T
    CLINICA CHIMICA ACTA, 1989, 180 (01) : 93 - 98
  • [33] AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS
    CHEN, CY
    GOTOH, M
    MAKINO, H
    SU, YC
    TAMIYA, E
    KARUBE, I
    ANALYTICA CHIMICA ACTA, 1992, 265 (01) : 5 - 14
  • [34] Needle-type multi-electrode array fabricated by MEMS technology for the hypodermic continuous glucose monitoring system
    Jung, MW
    Kim, DW
    Jeong, RA
    Kim, HC
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1987 - 1989
  • [35] Electrical Stimulation with a Needle-type Electrode Inserted into the Optic Nerve in Rabbit Eyes
    Hirokazu Sakaguchi
    Takashi Fujikado
    Hiroyuki Kanda
    Makoto Osanai
    Xiaoyun Fang
    Kazuaki Nakauchi
    Yasushi Ikuno
    Motohiro Kamei
    Masahito Ohji
    Tetsuya Yagi
    Yasuo Tano
    Japanese Journal of Ophthalmology, 2004, 48 : 552 - 557
  • [36] An approach to in situ detection of hydrogen peroxide:: Application of a commercial needle-type electrode
    Tamasko, Monika
    Nagy, Livia
    Mikolas, Esztella
    Molnar, Gergo A.
    Wittmann, Istvan
    Nagy, Geza
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (12) : 1533 - 1542
  • [37] Electrical stimulation with a needle-type electrode inserted into the optic nerve in rabbit eyes
    Sakaguchi, H
    Fujikado, T
    Kanda, H
    Osanai, M
    Fang, XY
    Nakauchi, K
    Ikuno, Y
    Kamei, M
    Ohji, M
    Yagi, T
    Tano, Y
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2004, 48 (06) : 552 - 557
  • [38] Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients
    Wentholt, IM
    Vollebregt, MA
    Hart, AA
    Hoekstra, JB
    DeVries, JH
    DIABETES CARE, 2005, 28 (12) : 2871 - 2876
  • [39] NEEDLE-TYPE GLUCOSE BIOSENSOR WITH AN ELECTROCHEMICALLY CODEPOSITED ENZYME IN A PLATINUM BLACK MATRIX
    ABDELHAMID, I
    ATANASOV, P
    WILKINS, E
    ELECTROANALYSIS, 1995, 7 (08) : 738 - 741
  • [40] Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ-Polyglutamic Acid
    Takaoka, Hiroki
    Yasuzawa, Mikito