Numerical Simulation of a Two-Stage Hybrid Heat Pump

被引:1
|
作者
Jeong, Siyoung [1 ]
Yun, Han-Gu [1 ]
Park, Kiwoong [1 ]
Park, Seong-Ryong [2 ]
Kim, Minsung [2 ]
机构
[1] Sogang Univ, Dept Mech Engn, Seoul, South Korea
[2] Korea Inst Energy Res, Daejeon, South Korea
关键词
Hybrid Heat Pump; Single-Stage; Two-Stage; Cycle Simulation;
D O I
10.3795/KSME-B.2010.34.2.191
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hybrid heat pumps, which combine the vapor compression and absorption heat pump cycle, can efficiently produce hot water of 80 degrees-90 degrees C from the low temperature of similar to 50 degrees C. In this study, the performance of a two-stage hybrid heat pump (HHP) was compared with a single-stage hybrid heat pump using EES (Engineering Equation Solver). For the same operating conditions, the two-stage HHP showed a slightly higher COP (Coefficient Of Performance) and more stable operating conditions than the single-stage HHP. Moreover, the maximum working fluid temperature of the two-stage HHP was found to be lower than that of the single-stage HHP by about 40 K, which makes the working conditions of the lubricating oil safer. The COPs of both systems decreased with increasing UA-values. However, the heat output of the HHP was increased at the same time.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 50 条
  • [21] Performance of two-stage variable capacity air source heat pump: Field performance results and TRNSYS simulation
    Safa, Amir A.
    Fung, Alan S.
    Kumar, Rakesh
    [J]. ENERGY AND BUILDINGS, 2015, 94 : 80 - 90
  • [22] Energy consumption simulation and analysis of the two-stage centrifugal vapor-compression water source heat pump
    Jin, Quan
    Shu, Haiwen
    Lin Duanmu
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 152 - 159
  • [23] A two-stage oil diffusion pump
    Henderson, JE
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1935, 6 (03): : 66 - 67
  • [24] Numerical Analysis of the Fluid Flow in the First Stage of a Two-Stage Centrifugal Pump With a Vaned Diffuser
    Stel, H.
    Amaral, G. D. L.
    Negrao, C. O. R.
    Chiva, S.
    Estevam, V.
    Morales, R. E. M.
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (07):
  • [25] Numerical analysis of two-stage axial blood pump based on blood damage
    Zhou, Bingjing
    Jing, Teng
    Wang, Fangqun
    He, Zhaoming
    [J]. Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2016, 33 (04): : 686 - 690
  • [26] Analysis and optimization of subcritical two-stage vapor injection heat pump systems
    Redon, A.
    Navarro-Peris, E.
    Pitarch, M.
    Gonzalvez-Macia, J.
    Corberan, J. M.
    [J]. APPLIED ENERGY, 2014, 124 : 231 - 240
  • [27] A modular approach to study the performance of a two-stage heat pump system for drying
    Chua, KJ
    Chou, SK
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) : 1363 - 1379
  • [28] Two-Stage Electrohydrodynamic Gas Pump for Heat Transfer Enhancement in a Square Channel
    Lin, S. C.
    Chang, Y. J.
    Wu, C. Y.
    Lai, F. C.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2022, 36 (03) : 492 - 499
  • [29] Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump
    Chaiyat, Nattaporn
    Kiatsiriroat, Tanongkiat
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2014, 4 (04) : 166 - 174
  • [30] RETRACTED: A novel configuration and performance for a two-stage thermoelectric heat pump system driven by a two-stage thermoelectric generator (Retracted Article)
    Chen, L.
    Meng, F.
    Sun, F.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 329 - 339