Induced Overvoltages on the SF6 Substation Enclosure Caused by Switching

被引:0
|
作者
Jonjic, Stjepan [1 ]
Baus, Zoran [1 ]
Barukcic, Marinko [1 ]
机构
[1] JJ Strossmayer Univ Osijek, Fac Elect Engn, Osijek, Croatia
关键词
enclosure voltage; switching; transient overvoltages;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates overvoltages on the SF6 substation enclosure caused by the switching operation of the interrupter. The paper analyzes the amplitude and the overvoltage duration on the substation enclosure. Switching overvoltages take part in the everyday drive of HV substations and constitute an undesired phenomenon that may often, beside transient disturbances, lead to undesired cases as well. Electrical discharge in the SF6 gas dielectric, caused by very fast overvoltages, spreads from the place of its occurrence towards all directions within the substation, which on discontinuities (e. g. connection bushings, cable bushings) also includes spreading onto the external side of the enclosure and earthed parts of the substation. Such overvoltages are characterized by a very high frequency for which even low inductances represent very high impedances. This paper is focused on simulation options of the transient connection GIS-overhead line in simulation software. Literature sources provide a fine description of the physical background of the observed phenomena. However, it is difficult to find a model presentation in certain software. Due to this fact, this paper shows possible ways of simulating the GIS-air connection with objects in ATP software.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [1] PROBLEMS WITH SWITCHING OVERVOLTAGES SOLVED BY THE SF6 SELF-EXTINGUISHING CIRCUIT-BREAKER
    BRAUN, D
    SATYANARAYANA, P
    GANZ, A
    BROWN BOVERI REVIEW, 1985, 72 (05): : 216 - 223
  • [2] The Influence of Atmospheric Overvoltages on High-Voltage SF6 Substations
    Vukasovic, Vedran
    Baus, Zoran
    Barukcic, Marinko
    INTERNATIONAL JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING SYSTEMS, 2011, 2 (01) : 17 - 24
  • [3] High Voltage SF6 Circuit Breaker Selection for a Substation
    Azam, A. B. M. Shafiul
    Schmidt, William Hal
    Elford, Kellie
    Vicklund, Kevin
    Dymond, Matt
    2022 IEEE PES GENERATION, TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION - LATIN AMERICA, IEEE PES GTD LATIN AMERICA, 2022,
  • [4] PACKAGE SUBSTATION SYSTEM TYPE ENK WITH SF6 INSULATION
    WIELAND, A
    KOGLIN, BB
    LEONHARDT, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 2300 - 2307
  • [5] An Algorithm for Estimation of SF6 Leakage on Power Substation Assets
    Castro Aranda, Ferley
    Garcia Sierra, Rodolfo
    Ceron Piamba, Andres Felipe
    Mailhe, Benjamin
    Gil, Luis Miguel Leon
    ALGORITHMS, 2022, 15 (02)
  • [6] 170 KV METALCLAD SF6 SWITCHGEAR FOR SEMPERSTEIG SUBSTATION
    SZENTEVARGA, HP
    BROWN BOVERI REVIEW, 1970, 57 (12): : 572 - +
  • [7] SF6 GAS INSULATED SUBSTATION FOR INDUSTRIAL USE.
    Miwada, Satoshi
    Maruyama, Seiichi
    Daimon, Goro
    Ando, Toshio
    Hitachi Review, 1975, 24 (07): : 311 - 320
  • [8] SWITCHING SURGE OF SHUNT REACTOR CAUSED BY SF6 CIRCUIT-BREAKER OPERATION
    KAWADA, H
    GOTO, K
    HANAMURA, M
    YANABU, S
    NISHIWAKI, S
    UEDA, T
    MURAYAMA, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1987, 2 (04) : 1124 - 1130
  • [9] Movement of particles in compressed SF6 GIS with dielectric coated enclosure
    Prakash, KS
    Srivastava, KD
    Morcos, MM
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (03) : 344 - 347
  • [10] SF6 SWITCHGEAR FOR OUTDOOR AND INDOOR SWITCHING STATIONS
    KESSLER, C
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1973, 275 (1248): : 109 - 120