THE MEASUREMENT OF CHANNELING RADIATION FROM A LINEAR-ACCELERATOR ELECTRON-BEAM AT HIGH CURRENTS

被引:4
|
作者
GARY, CK [1 ]
FISHER, AS [1 ]
PANTELL, RH [1 ]
HARRIS, J [1 ]
PIESTRUP, MA [1 ]
机构
[1] ADELPHI TECHNOL INC,PALO ALTO,CA 94301
关键词
D O I
10.1016/0168-583X(90)90568-F
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we describe the instrumentation used in the production and detection of channeling radiation from a linear-accelerator electron beam at high currents. Channeling-radiation spectra were measured for 30 meV electrons channeled along the (100) and (110) planes of a 15 μm thick silicon crystal. Spectra were taken for photon energies from 10 to 38 keV with a 0.2 keV resolution in 5 minutes. Using an average electron current of 3 μA, over 109 channeling photons/s were incident on the spectrometer, eliminating single-pulse counting as a means of spectral measurement, since collimation to 10-11 sr would have been necessary to avoid pileup. The bremsstrahlung radiation emitted from the channeling target crystal produced a high-energy noise background. A Bragg spectrometer, using a mosaic-spread Bragg crystal, was designed to measure the intense channeling-radiation X-rays in the noisy environment. This spectrometer provides a means to measure intense channeling-radiation spectra from any achievable electron current. © 1990.
引用
收藏
页码:458 / 465
页数:8
相关论文
共 50 条
  • [21] RADIATION LEAKAGE FROM ELECTRON APPLICATOR ASSEMBLY ON A LINEAR-ACCELERATOR
    SCHNEIDER, AJ
    MEDICAL PHYSICS, 1982, 9 (05) : 761 - 762
  • [22] CHARACTERIZATION OF A VARIABLE ELECTRON-BEAM COLLIMATOR FOR THE SIEMENS MEVATRON-77 LINEAR-ACCELERATOR
    GRIGGS, PS
    BLINICK, JS
    MEDICAL PHYSICS, 1981, 8 (05) : 737 - 737
  • [23] POSSIBLE DOSE ERROR FROM VARIATION IN ELECTRON-BEAM COLLIMATOR SETTING CLINAC 18 LINEAR-ACCELERATOR
    WRIGHT, AE
    THOMSON, L
    OLSON, MH
    RAY, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1976, : 96 - 96
  • [24] ELECTRON-BEAM IN A LINEAR INDUCTION ACCELERATOR
    MATORA, IM
    MERKULOV, LA
    SHELONTS.II
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1972, 16 (07): : 1155 - &
  • [26] AN INTRACAVITARY CONE SYSTEM FOR ELECTRON-BEAM THERAPY USING A THERAC-20 LINEAR-ACCELERATOR
    WILSON, DL
    SHARMA, SC
    JOSE, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (06): : 1007 - 1011
  • [27] CHARACTERISTICS OF AN INTRA-ORAL CONE FOR ELECTRON-BEAM THERAPY WITH AN 18 MEV LINEAR-ACCELERATOR
    WEXLER, MC
    TOBOCHNIK, N
    SPIEGLER, P
    HERMAN, MW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (11): : 2001 - 2004
  • [28] AN INTRACAVITARY CONE SYSTEM FOR ELECTRON-BEAM THERAPY USING THERAC-20 LINEAR-ACCELERATOR
    SHARMA, SC
    WILSON, DL
    JOSE, B
    LINDBERG, RD
    MEDICAL PHYSICS, 1984, 11 (03) : 403 - 403
  • [29] COMPARISON OF 3-DIMENSIONAL MONTE-CARLO SIMULATION AND THE PENCIL BEAM ALGORITHM FOR AN ELECTRON-BEAM FROM A LINEAR-ACCELERATOR
    MANFREDOTTI, C
    NASTASI, U
    RAGONA, R
    ANGLESIO, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (1-2): : 355 - 359
  • [30] Betatron Radiation Based Measurement of the Electron-Beam Size in a Wakefield Accelerator
    Schnell, Michael
    Saevert, Alexander
    Landgraf, Bjoern
    Reuter, Maria
    Nicolai, Maria
    Jaeckel, Oliver
    Peth, Christian
    Thiele, Tobias
    Jansen, Oliver
    Pukhov, Alexander
    Willi, Oswald
    Kaluza, Malte C.
    Spielmann, Christian
    LIGHT AT EXTREME INTENSITIES 2011, 2012, 1462 : 231 - 234