THE MEASUREMENT OF CHANNELING RADIATION FROM A LINEAR-ACCELERATOR ELECTRON-BEAM AT HIGH CURRENTS

被引:4
|
作者
GARY, CK [1 ]
FISHER, AS [1 ]
PANTELL, RH [1 ]
HARRIS, J [1 ]
PIESTRUP, MA [1 ]
机构
[1] ADELPHI TECHNOL INC,PALO ALTO,CA 94301
关键词
D O I
10.1016/0168-583X(90)90568-F
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we describe the instrumentation used in the production and detection of channeling radiation from a linear-accelerator electron beam at high currents. Channeling-radiation spectra were measured for 30 meV electrons channeled along the (100) and (110) planes of a 15 μm thick silicon crystal. Spectra were taken for photon energies from 10 to 38 keV with a 0.2 keV resolution in 5 minutes. Using an average electron current of 3 μA, over 109 channeling photons/s were incident on the spectrometer, eliminating single-pulse counting as a means of spectral measurement, since collimation to 10-11 sr would have been necessary to avoid pileup. The bremsstrahlung radiation emitted from the channeling target crystal produced a high-energy noise background. A Bragg spectrometer, using a mosaic-spread Bragg crystal, was designed to measure the intense channeling-radiation X-rays in the noisy environment. This spectrometer provides a means to measure intense channeling-radiation spectra from any achievable electron current. © 1990.
引用
下载
收藏
页码:458 / 465
页数:8
相关论文
共 50 条
  • [1] DIAGNOSTICS OF AN ELECTRON-BEAM OF A LINEAR-ACCELERATOR USING COHERENT TRANSITION RADIATION
    SHIBATA, Y
    TAKAHASHI, T
    KANAI, T
    ISHI, K
    IKEZAWA, M
    OHKUMA, J
    OKUDA, S
    OKADA, T
    PHYSICAL REVIEW E, 1994, 50 (02): : 1479 - 1484
  • [2] STABILITY OF A LINEAR-ACCELERATOR WITH ACHROMATIC ELECTRON-BEAM BENDING
    SUTHERLAND, WH
    BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (579): : 262 - 266
  • [3] TIME STRUCTURE MONITORING OF THE ELECTRON-BEAM IN A LINEAR-ACCELERATOR
    OWAKI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1983, 22 (04): : 723 - 727
  • [4] EXPERIMENTAL-OBSERVATION OF RADIATION LOSS OF A SINGLE BUNCH ELECTRON-BEAM IN A LINEAR-ACCELERATOR
    TAKEDA, S
    KAWANISHI, M
    HAYASHI, K
    SAKURAI, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 188 (01): : 1 - 8
  • [5] EVALUATION OF ELECTRON-BEAM UNIFORMITY DURING COMMISSIONING OF A LINEAR-ACCELERATOR
    MANDELZWEIG, Y
    FEYGELMAN, V
    MEDICAL PHYSICS, 1993, 20 (04) : 1233 - 1236
  • [6] PARAMETRIZATION OF LINEAR-ACCELERATOR ELECTRON-BEAM FOR COMPUTERIZED DOSIMETRY CALCULATIONS
    MILLAN, PE
    MILLAN, S
    HERNANDEZ, A
    ANDREO, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (04): : 825 - 827
  • [7] PARAMETERIZATION OF THE ELECTRON-BEAM OUTPUT FACTORS OF A 25 MEV LINEAR-ACCELERATOR
    MCPARLAND, BJ
    MEDICAL PHYSICS, 1987, 14 (03) : 474 - 474
  • [8] DESIGN OF METALLIC ELECTRON-BEAM CONES FOR AN INTRAOPERATIVE THERAPY LINEAR-ACCELERATOR
    HOGSTROM, KR
    BOYER, AL
    SHIU, AS
    OCHRAN, TG
    KIRSNER, SM
    KRISPEL, F
    RICH, T
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05): : 1223 - 1232
  • [9] EVALUATION OF A PHOTON AND AN ELECTRON-BEAM OF A 6-MV LINEAR-ACCELERATOR
    SHARMA, SC
    MODUR, P
    BASAVATIA, R
    MEDICAL PHYSICS, 1988, 15 (04) : 525 - 529
  • [10] TEMPERATURE-PRESSURE COMPENSATION FOR A LINEAR-ACCELERATOR ELECTRON-BEAM DOSIMETER
    HREJSA, AF
    SOEN, J
    JANKOWIAK, P
    MEDICAL PHYSICS, 1985, 12 (02) : 260 - 261