ELECTRONIC CANAL LENGTH MEASUREMENT

被引:55
|
作者
KOBAYASHI, C
机构
[1] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo
关键词
D O I
10.1016/S1079-2104(05)80288-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The most important advantage of the electronic method is that it can measure the length of the root canal to the end of the apical foramen, not to the radiographic apex. The most striking disadvantage of the electronic method is that if strong electrolytes are in the root canal, the meter shows a reading that is too high (obtaining a short working length), or sometimes the measurement itself becomes impossible. Recently new electronic devices have been developed. These devices can make an accurate measurement of the root canal length, even if a strong electrolyte is present in the root canal. These new devices allow the dentist to enlarge the apical portion of the canal more precisely than when the radiographic method is used.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [21] Erratum to: An ex vivo comparison of working length determination by three electronic root canal length measurement devices integrated into endodontic rotary motors
    Manal Maree-Ali
    Ronald Wigler
    Shaul Lin
    Arieh Y. Kaufman
    Clinical Oral Investigations, 2016, 20 : 2309 - 2309
  • [22] VARIABLES AFFECTING ELECTRONIC ROOT-CANAL MEASUREMENT
    WU, YN
    SHI, JN
    HUANG, LZ
    XU, YY
    INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (02) : 88 - 92
  • [23] Evaluation of an in vitro model of electronic root canal measurement
    Stare, Z
    Lackovic, I
    Galic, N
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 1047 - 1050
  • [24] An In Vitro Evaluation of Performance of Two Electronic Root Canal Length Measurement Devices during Retreatment of Different Obturating Materials
    Aggarwal, Vivek
    Singla, Mamta
    Kabi, Debipada
    JOURNAL OF ENDODONTICS, 2010, 36 (09) : 1526 - 1530
  • [25] In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II
    Somma, F.
    Castagnola, R.
    Lajolo, C.
    Holtzman, L. Paterno
    Marigo, L.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (06) : 552 - 556
  • [26] In Vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II
    Altenburger, M. J.
    Tchorz, J. P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (11) : 1053 - 1053
  • [27] BASIC STUDIES OF ELECTRONIC METHOD FOR MEASURING THE ROOT-CANAL LENGTH
    TAKEI, M
    HASEGAWA, K
    OHASHI, M
    JOURNAL OF DENTAL RESEARCH, 1983, 62 (04) : 470 - 470
  • [28] An in vivo evaluation of reliability of electronic root canal length measuring device
    Ramos, CAS
    Bernardineli, N
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B98 - B98
  • [29] THE EFFECT OF INSTRUMENTATION ON ROOT-CANAL LENGTH AS MEASURED WITH AN ELECTRONIC DEVICE
    FARBER, JP
    BERNSTEIN, M
    JOURNAL OF ENDODONTICS, 1983, 9 (03) : 114 - 115
  • [30] The assessment of the agreement of root canal measurement by the radiological and the electronic method
    Krupinski, J
    Slowik, J
    Gandurska, M
    Maga, I
    Lipinska, A
    Michalik, K
    Zarow, M
    Geroch, E
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1225 - 1225