共 50 条
ECHOCARDIOGRAPHIC ANALYSIS OF CARDIAC-FUNCTION DURING HIGH PEEP VENTILATION
被引:34
|作者:
BERGLUND, JE
HALDEN, E
JAKOBSON, S
LANDELIUS, J
机构:
[1] UNIV HOSP UPPSALA,DEPT CLIN PHYSIOL,UPPSALA,SWEDEN
[2] UNIV HOSP UPPSALA,DEPT CLIN RES 2,UPPSALA,SWEDEN
关键词:
CARDIAC OUTPUT;
VENTRICULAR FUNCTION;
POSITIVE END-EXPIRATORY PRESSURE;
ECHOCARDIOGRAPHY;
D O I:
10.1007/BF01704696
中图分类号:
R4 [临床医学];
学科分类号:
1002 ;
100602 ;
摘要:
Objective: Does positive end-expiratory pressure ventilation (PEEP) deteriorate cardiac contractility? Design: By means of echocardiography nine piglets were studies during ventilation with 0, 15 and 25 cmH2O (PEEP). Recordings were made before and after 500 ml of 6% dextran 70. Measurement and results: Right and left ventricular end-diastolic diameters were plotted against the stroke volume determined by the thermodilution technique. By combining observations made before and after volume expansion during the different ventilation modes, a ventricular function curve was obtained. The slopes of the curves were similar during all three ventilation modes, both on the left and on the right side. Conclusion: This study indicates undisturbed myocardial contractility during PEEP ventilation. We infer that the cardiac output deterioration in the intact animal is caused entirely by impairment of venous return.
引用
收藏
页码:174 / 180
页数:7
相关论文