Evaluation of the Effect of Low Level Laser Therapy Toothbrush in Treatment of Dentin Hypersensitivity

被引:0
|
作者
Yaghini, Jaber [1 ]
Mogharehabed, Ahmad [2 ]
Safavi, Nassimeh [3 ]
Mohamadi, Mehrnush [4 ]
Ashtiju, Fahime [4 ]
机构
[1] Isfahan Univ Med Sci, Sch Dent, Dept Periodont, Dent Mat Res Ctr, Esfahan, Iran
[2] Isfahan Univ Med Sci, Sch Dent, Dept Periodont, Dent Implannts Res Ctr, Esfahan, Iran
[3] Shahid Beheshti Univ Med Sci, Laser Applicat Med Sci Res Ctr, Tehran, Iran
[4] Esfahan Univ Med Sci, Sch Dent, Esfahan, Iran
关键词
diode laser; hypersensitivity; dentin; laser therapy; low level;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Dentin hypersensitivity is one of the most common complications that affect patients after periodontal therapy. Recently low level laser therapy has been introduced as a new treatment modality and has produced beneficial results. The purpose of this study is to evaluate the effect of low level laser therapy toothbrushes in reduction of dentin hypersensitivity. Methods: In this pilot interventional controlled clinical trial, 40 patients suffering from dentin hypersensitivity were selected using simple randomization. Half of the patients were given laser toothbrushes and the other half was given non-laser sensodyne toothbrushes. Primary dentin hypersensitivity was recorded by visual analogue scale (VAS) score and ice spray. Then dentin hypersensitivity was measured right after the treatment as well az in the intervals of 1 month and 2 months after initiation of the study. Data were compared using Statistical Package for the Social Sciences (SPSS) software and Analysis of variance (ANOVA) paired T test. Results: The results of this study showed that there was a significant difference in each of the two kinds of tooth brushes separately for all time intervals (P < 0.001). Also the effect of the type of toothbrush was investigated using before treatment VAS with covariance analyses. P values for immediately, 1 month and 2 months after treatment were calculated to be 0.078, 0.02, 0.01 respectfully. Also the effect of the toothbrush type was significant in the manner that laser toothbrushes reduce dentin hypersensitivity more than ordinary toothbrushes (P<0.05). Conclusion: Both sensodyne and laser tooth brushes improve dentin hypersensitivity, although the laser toothbrush led to better results in short.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [41] Evaluation of Efficacy of Low-Level Laser Therapy
    Mansouri, Vahid
    Arjmand, Babak
    Tavirani, Mostafa Rezaei
    Razzaghi, Mohammadreza
    Rostami-Nejad, Mohammad
    Hamdieh, Mostafa
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2020, 11 (04) : 369 - 380
  • [42] Effect of Low-Level Laser Therapy in Reducing Dentinal Hypersensitivity and Pain Following Periodontal Flap Surgery
    Doshi, Shreya
    Jain, Sanjay
    Hegde, Rashmi
    PHOTOMEDICINE AND LASER SURGERY, 2014, 32 (12) : 700 - 706
  • [43] Dentin hypersensitivity treatment by CO2 laser -: the influence of the densities of dentin tubules and the laser beam incidence
    Colojoara, C
    Gabay, S
    van der Meulen, FW
    van Gemert, MJC
    Miron, M
    Mavrantoni, A
    MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, OPHTHALMOLOGY, DENTISTRY, AND ENDOSCOPY, PROCEEDINGS OF, 1997, 3192 : 40 - 50
  • [44] In vivo and in situ evaluation of innovative approaches in dentin hypersensitivity treatment
    Heba Abd El-Fattah Mohamed
    Dina Ezzeldin Mohamed
    Elhassan Hassanein
    Heba El-din Salah El-din Hamza
    BMC Oral Health, 25 (1)
  • [45] Low level laser therapy wound treatment update
    Sliney, D
    JOURNAL OF LASER APPLICATIONS, 1999, 11 (05) : 221 - 224
  • [46] Application of the low level laser therapy for the treatment of vaginitis
    Passeniouk, AM
    Mikhailov, VA
    LASER FLORENCE '99: A WINDOW ON THE LASER MEDICINE WORLD, 1999, 1 (37): : 316 - 318
  • [47] THE APPLICATION OF LOW LEVEL LASER THERAPY FOR THE TREATMENT OF ONYCHOMYCOSIS
    Zang, Kerry
    Shanks, Steve
    Maloney, Ryan
    LASERS IN SURGERY AND MEDICINE, 2012, 44 : 53 - 54
  • [48] Evaluation of Bioactive Glass Treatment for Dentin Hypersensitivity: A Systematic Review
    Petrovic, Dorotea
    Galic, Dora
    Seifert, Davor
    Lesic, Nikolina
    Smolic, Martina
    BIOMEDICINES, 2023, 11 (07)
  • [49] Comparative Evaluation of the Effects of Nd:YAG Laser and a Desensitizer Agent on the Treatment of Dentin Hypersensitivity: A Clinical Study
    Lopes, Anely Oliveira
    Correa Aranha, Ana Cecilia
    PHOTOMEDICINE AND LASER SURGERY, 2013, 31 (03) : 132 - 138
  • [50] Ozone and Laser Effects on Dentin Hypersensitivity Treatment: A Randomized Clinical Study
    D'Amario, Maurizio
    Di Carlo, Mariachiara
    Jahjah, Ali
    Mauro, Stefania
    Natale, Salvatore
    Capogreco, Mario
    JOURNAL OF ENDODONTICS, 2024, 50 (05) : 554 - 561