COMPARISON OF PULPAL BLOOD-FLOW IN DOG CANINE TEETH DETERMINED BY THE LASER DOPPLER AND THE XE-133 WASHOUT METHODS

被引:37
|
作者
KIM, S [1 ]
LIU, M [1 ]
MARKOWITZ, K [1 ]
BILOTTO, G [1 ]
DORSCHERKIM, J [1 ]
机构
[1] COLUMBIA UNIV, SCH BEHAV PHYSIOL, ORAL PHYSIOL LAB, NEW YORK, NY 10032 USA
关键词
!sup]133[!/sup]Xe washout method; laser Doppler flowmetry; norepinephrine; pulpal blood flow;
D O I
10.1016/0003-9969(90)90189-H
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Pulpal blood flow measurements by laser Doppler flowmetry were compared with those made simultaneously and on the same teeth by the 133Xe washout method. Pulpal blood flow in the resting state was 82.4 ml/min per 100 g as calculated from the fast component of the 133Xe washout, whereas laser Doppler flowmetry recorded 263 mV. The close intra-arterial (i.a.) injection of the vasoconstrictor norepinephrine (10-2-10-1 μg/kg) caused a reduction of pulpal blood flow by 20.2% with the 133Xe washout and by 9.7% with the laser Doppler flowmetry in 6 observations in 4 dogs. The laser Doppler flowmetry measurements of these norepinephrine-induced changes correlated significantly with changes measured by the 133Xe washout method as analysed by linear regression (p = 0.004). © 1990.
引用
收藏
页码:411 / 413
页数:3
相关论文
共 50 条
  • [21] COMPARISON OF MICROSPHERES AND XE-133 CLEARANCE IN MEASUREMENTS OF BLOOD-FLOW
    MARCUS, ML
    HEISTAD, DD
    BISCHOF, CJ
    FEDERATION PROCEEDINGS, 1978, 37 (03) : 733 - 733
  • [22] CEREBRAL BLOOD-FLOW IN THE NEWBORN-INFANT - COMPARISON OF DOPPLER ULTRASOUND AND XE-133 CLEARANCE
    GREISEN, G
    JOHANSEN, K
    ELLISON, PH
    FREDRIKSEN, PS
    MALI, J
    FRIISHANSEN, B
    JOURNAL OF PEDIATRICS, 1984, 104 (03): : 411 - 418
  • [23] MEASUREMENT OF BLOOD-FLOW IN THE DENTAL-PULP OF DOGS WITH THE XE-133 WASHOUT METHOD
    KIM, S
    SCHUESSLER, G
    CHIEN, S
    ARCHIVES OF ORAL BIOLOGY, 1983, 28 (06) : 501 - 505
  • [24] MEASUREMENT OF BONE BLOOD-FLOW WITH A XE-133 WASHOUT METHOD - PRELIMINARY-REPORT
    LAHTINEN, T
    KARJALAINEN, P
    ALHAVA, EM
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1979, 4 (06): : 435 - 439
  • [25] MUSCLE BLOOD-FLOW IN EXERCISING DOGS MEASURED BY XE-133 WASHOUT AND BY MICROSPHERE TRAPPING
    CERRETELLI, P
    PENDERGAST, D
    ELLIS, A
    KRASNEY, J
    RENNIE, DW
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 945 - 945
  • [26] CEREBRAL BLOOD-FLOW TOMOGRAPHY WITH XE-133
    LASSEN, NA
    SEMINARS IN NUCLEAR MEDICINE, 1985, 15 (04) : 347 - 356
  • [27] BLOOD-FLOW MEASUREMENT IN MUSCLE WITH XE-133
    CHUNG, SY
    KIM, I
    RYO, UY
    MASKIN, C
    PINSKY, S
    RADIOLOGY, 1987, 165 (02) : 571 - 572
  • [28] MUCOSAL SUBMUCOSAL BLOOD-FLOW IN THE SMALL-INTESTINE IN PIGS DETERMINED BY LOCAL WASHOUT OF XE-133 AND MICROSPHERE TECHNIQUES
    MORTENSEN, PE
    OLSEN, J
    SEJRSEN, P
    BULOW, J
    EDELFORS, S
    ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 139 (02): : 311 - 317
  • [29] CHANGES IN BLOOD-FLOW OF GROWING EXPERIMENTAL TUMOR DETERMINED BY THE CLEARANCE OF XE-133
    SIRACKA, E
    PAPPOVA, N
    PIPA, V
    DURKOVSKY, J
    NEOPLASMA, 1979, 26 (02) : 173 - 177
  • [30] RENAL BLOOD-FLOW AND INTRA-RENAL BLOOD-FLOW DISTRIBUTION ASSESSED BY XE-133 WASHOUT TECHNIQUE IN MAN
    KOLSTERS, G
    DEGRAAF, CN
    NETHERLANDS JOURNAL OF MEDICINE, 1978, 21 (04): : 188 - 195