HPLC-ELECTROCHEMICAL DETECTOR WITH A CARBON-FIBER WORKING ELECTRODE

被引:3
|
作者
MATTUSCH, J
WELSCH, T
WERNER, G
机构
来源
关键词
D O I
10.1002/prac.19923340109
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The paper describes an electrochemical detector with carbon fibers as the working electrode placed perpendicularly to the flow direction. The detector performance was characterized by the detection limit for selected phenolic compounds, reproducibility, linearity and the signal dependence on the flow rate. An electrochemical in situ pretreatment of the working electrode improves sensitivity and long term stability.
引用
收藏
页码:49 / 52
页数:4
相关论文
共 50 条
  • [31] A SIMPLIFIED METHOD FOR SELECTING A CARBON-FIBER ELECTRODE IN PULSE VOLTAMMETRY
    LIAO, BY
    LIO, HP
    WANG, CY
    YOUNG, MS
    HO, MT
    LIN, MT
    JOURNAL OF NEUROSCIENCE METHODS, 1993, 50 (03) : 291 - 299
  • [32] ELECTROWINNING STUDY OF GALENA CONCENTRATE WITH A CARBON-FIBER BAG ELECTRODE
    BOSE, S
    ACHARYA, HN
    BANERJEE, HD
    SIRCAR, SC
    HYDROMETALLURGY, 1989, 22 (1-2) : 273 - 279
  • [33] LIGHTWEIGHT, STABLE, AND RECHARGEABLE BATTERY WITH AN ACTIVATED CARBON-FIBER ELECTRODE
    NOGAMI, T
    NAWA, M
    MIKAWA, H
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1982, (20) : 1158 - 1159
  • [34] ELECTRICAL-PROPERTIES OF THE CARBON-FIBER ELECTRODE AND ITS APPLICATION
    SHIGEMITSU, T
    NAGATA, T
    MATSUMOTO, G
    TSUKAHARA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (03) : 359 - 362
  • [35] THE SENSITIVITY OF CARBON-FIBER MICROELECTRODES USED FOR THE ELECTROCHEMICAL DETECTION OF CATECHOLAMINES
    ARMSTRONGJAMES, M
    KRUK, ZL
    MILLAR, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1980, 308 (NOV): : P115 - P116
  • [36] VOLTAMMETRY OF ADENOSINE AFTER ELECTROCHEMICAL TREATMENT OF CARBON-FIBER ELECTRODES
    CHEN, TK
    STREIN, TG
    ABE, T
    EWING, AG
    ELECTROANALYSIS, 1994, 6 (09) : 746 - 751
  • [37] ELECTROCHEMICAL-BEHAVIOR OF SYNTHETIC LIPID MODIFIED CARBON-FIBER ELECTRODE - AMPEROMETRIC DETECTION OF CA2+
    HUSSAM, A
    SIDDIQUE, SH
    QUTUBUDDIN, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 25 - ANYL
  • [38] Electrochemical Behavior and Determination of Salicylic Acid at Carbon-fiber Electrodes
    Park, Jinwoo
    Eun, Changsun
    ELECTROCHIMICA ACTA, 2016, 194 : 346 - 356
  • [39] 6 CHANNEL ELECTROCHEMICAL HPLC DETECTOR USING GRAPHITE REINFORCEMENT CARBON ELECTRODE FOR DETERMINATION OF CATECHOLAMINE METABOLITES
    KUSU, F
    TAKAGI, H
    YUASA, K
    TAKAMURA, K
    BUNSEKI KAGAKU, 1992, 41 (10) : 497 - 502
  • [40] SUB-NANOGRAM N-CHLORAMINES BY HPLC-ELECTROCHEMICAL DETECTION
    JERSEY, JA
    JOHNSON, JD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 37 - ENVR