GENOTOXIC AND MUTAGENIC EFFECTS OF THE DIAGNOSTIC USE OF TL-201 IN NUCLEAR-MEDICINE

被引:14
|
作者
KELSEY, KT
DONOHOE, KJ
BAXTER, B
MEMISOGLU, A
LITTLE, JB
CAGGANA, M
LIBER, HL
机构
[1] HARVARD UNIV,SCH PUBL HLTH,RADIOL LAB,BOSTON,MA 02115
[2] BETH ISRAEL HOSP,DEPT RADIOL,DIV NUCL MED,BOSTON,MA 02215
来源
MUTATION RESEARCH | 1991年 / 260卷 / 03期
关键词
TL-201; HPRT MUTATION; CHROMOSOME ABERRATIONS;
D O I
10.1016/0165-1218(91)90032-H
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
In order to investigate possible mutagenic effects of in vivo exposure to low levels of ionizing radiation used in nuclear medicine, we have examined the hypoxanthine guanine phosphoribosyl transferase (hprt) mutant fraction (MF) and chromosome aberration (CA) frequency in 24 nuclear medicine patients before and after injection of thallium-201. The mean MF of the thallium-201-exposed cohort was 5.2 +/- 4.4 x 10(-6) before injection exposure. No significant difference in MF was observed 24 h later. In 11 patients who were studied on a third occasion, 30 days after thallium-201 exposure, there was again no significant difference in post-exposure as compared with the pre-exposure MF. The frequency of CA in peripheral blood lymphocytes was not significantly different, comparing pre- and 24 h to 1 month post-radionuclide exposure. Thus, thallium-201 exposure was not associated with significant elevations in MF or CA frequency in lymphocytes of exposed individuals.
引用
下载
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [21] USE OF COMPUTERS IN NUCLEAR-MEDICINE
    BELL, PR
    DILLON, RS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 15 - 19
  • [22] EFFECTS OF REDUCED CORONARY FLOW ON TL-201 WASHOUT
    GOLDHABER, SZ
    POHOST, GM
    ALPERT, NM
    NEWELL, JB
    CYWINSKI, LM
    INGWALL, JS
    FOSSEL, ET
    CIRCULATION, 1981, 64 (04) : 241 - 241
  • [23] EFFECTS OF DIPYRIDAMOLE ON REGIONAL MYOCARDIAL DISTRIBUTION OF TL-201
    WODARCYK, MA
    GOODENDAY, LS
    BREWSTER, P
    MUSWICK, G
    NELSON, AD
    HOLTGRIEVE, C
    SOMANI, P
    LEIGHTON, RF
    CLINICAL RESEARCH, 1983, 31 (02): : A255 - A255
  • [24] Diagnostic value of Tl-201 lung uptake is dependent on measurement method
    Hitzel, A
    Manrique, A
    Cribier, A
    Véra, P
    JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (03) : 332 - 338
  • [25] Diagnostic value of TL-201 lung uptake is dependent on measurement method
    Anne Hitzel
    Alain Manrique
    Alain Cribier
    Pierre Véra
    Journal of Nuclear Cardiology, 2001, 8 : 332 - 338
  • [26] EXERCISE TL-201 SCINTIGRAPHY - EVALUATION OF THE ADDITIONAL DIAGNOSTIC-VALUE
    OOSTERHUIS, WP
    NIEMEYER, MG
    BREEMAN, A
    ZWINDERMAN, AH
    ASCOOP, CAPL
    VERZIJLBERGEN, FJ
    KUIJPER, AFM
    VANDERWALL, EE
    PAUWELS, EKJ
    NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (02) : 87 - 95
  • [27] IMPROVING THE DIAGNOSTIC-ACCURACY OF TL-201 IMAGING OF INTRACRANIAL TUMORS
    ELGAZZAR, AH
    CLINICAL NUCLEAR MEDICINE, 1995, 20 (04) : 389 - 389
  • [28] A NEW PROBABILISTIC METHOD FOR DIAGNOSTIC INTERPRETATION OF QUANTITATIVE TL-201 SCINTIGRAPHY
    KIAT, H
    MADDAHI, J
    VANTRAIN, K
    RESSER, K
    AREEDA, J
    WONG, C
    CIRCULATION, 1987, 76 (04) : 485 - 485
  • [29] TL-201 FOR MEDICAL USE .2. BIOLOGIC BEHAVIOR
    BRADLEYMOORE, PR
    LEBOWITZ, E
    GREENE, MW
    ATKINS, HL
    ANSARI, AN
    JOURNAL OF NUCLEAR MEDICINE, 1975, 16 (02) : 156 - 160
  • [30] USE OF TL-201 SPECT TO QUANTITATE MALIGNANCY GRADE OF GLIOMAS
    BLACK, KL
    HAWKINS, RA
    KIM, KT
    BECKER, DP
    LERNER, C
    MARCIANO, D
    JOURNAL OF NEUROSURGERY, 1989, 71 (03) : 342 - 346