THE NOISE OF THE MAGNETIC BOLOMETER

被引:8
|
作者
BUHLER, M
UMLAUF, E
机构
[1] Walther-Meissner-Institut für Tieftemperaturforschung der Bayerischen Akademie, der Wissenschaften, Garching, D 85748
关键词
D O I
10.1007/BF00693498
中图分类号
O59 [应用物理学];
学科分类号
摘要
We discuss a thermal detector consisting Of an absorber of pure insulating material and a sensor being a paramagnetic sample in a small magnetic field. Upon absorption of a particle and thermalization of its energy the magnetic moment M of the sensor decreases and DELTAM is measured very sensitively with a SQUID. This detector has the unique property that no power of measurement is applied and therefore it is possible and favourable to make the signal decay time much longer than the signal rise time. With that we obtain frequency spectra of the noise and of the signal, which show that the uncertainty of energy deltaE is not limited by the so-called thermodynamic limit. The limits of energy resolution are estimated in particular with respect to high detector masses.
引用
收藏
页码:697 / 702
页数:6
相关论文
共 50 条
  • [21] Bolometer developments in diagnostics for magnetic confinement fusion
    Meister, H.
    Bernert, M.
    Biel, W.
    Han, M.
    Ingesson, L. C.
    Mukai, K.
    Penzel, F.
    Peterson, B. J.
    Reichle, R.
    Reinke, M. L.
    Schmitt, S.
    Zhang, D.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [22] MAGNETIC STABILIZATION OF OPERATING POINT OF A SUPERCONDUCTING BOLOMETER
    ZAITSEV, GA
    STASHKOV, VG
    KREBTOV, IA
    CRYOGENICS, 1976, 16 (07) : 440 - 441
  • [23] MAGNETIC STABILIZATION OF OPERATING POINT IN A SUPERCONDUCTING BOLOMETER
    ZAITSEV, GA
    STASHKOV, VG
    KHREBTOV, IA
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1975, (05): : 210 - 211
  • [24] SIGNAL RISE-TIME OF THE MAGNETIC BOLOMETER
    FAUSCH, T
    BUHLER, M
    UMLAUF, E
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1993, 93 (3-4) : 703 - 708
  • [25] Design of a bolometer for Hanbit magnetic mirror device
    Yoo, SJ
    Choi, S
    Kwon, M
    Lee, S
    Oh, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 920 - 922
  • [26] Bolometer detection of magnetic resonances in nanoscaled objects
    Rod, Irina
    Meckenstock, Ralf
    Zaehres, Horst
    Derricks, Christian
    Mushenok, Fedor
    Reckers, Nathalie
    Kijamnajsuk, Puchong
    Wiedwald, Ulf
    Farle, Michael
    NANOTECHNOLOGY, 2014, 25 (42)
  • [27] A MAGNETIC BOLOMETER FOR SINGLE-PARTICLE DETECTION
    BUHLER, M
    UMLAUF, E
    EUROPHYSICS LETTERS, 1988, 5 (04): : 297 - 301
  • [28] Study of the effect of external noise pickups on the performance of a cryogenic bolometer
    Garai, A.
    Reza, A.
    Mazumdar, A.
    Krishnamoorthy, H.
    Gupta, G.
    Pose, M. S.
    Mallikarjunachary, S.
    Nanal, V
    Pillay, R. G.
    Ramakrishnan, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (09):
  • [29] Low noise cryogenic electronics: Preamplifier configurations with feedback on the bolometer
    Yvon, D
    Sushkov, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (02) : 428 - 437
  • [30] Low noise cryogenic electronics: Preamplifier configurations with feedback on the bolometer
    Yvon, D.
    Sushkov, V.
    IEEE Transactions on Nuclear Science, 2000, 47 (2 II) : 428 - 437