A THICKNESS INDEPENDENT RADIOCHROMIC FILM DOSIMETRY SYSTEM

被引:1
|
作者
RICKEY, JD
HUMPHERYS, KC
机构
[1] Far West Technology, Inc., Goleta, CA 93117
来源
RADIATION PHYSICS AND CHEMISTRY | 1993年 / 42卷 / 4-6期
关键词
ABSORBED DOSE; DOSIMETRY; ELECTRON BEAM; GAMMA-RADIATION; IONIZING RADIATION; QUALITY CONTROL; RADIATION PROCESSING; RADIOCHROMIC DOSIMETRY; RADIOCHROMIC FILM;
D O I
10.1016/0969-806X(93)90366-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new radiochromic thin film dosimeter has been developed for use in radiation processing. The dosimeter's properties are similar to diose of the commercially available FWT-60-00 Radiachromic Detectors with three key differences: 1) a lower sensitivity allows reading the optical density at the peak of the absorbtion spectrum (ca. 600 nm) for absorbed doses to over 50 kGy, 2) a radiation-insensitive dye additive allows for automatic thickness correction, and 3) another additive extends to higher doses the agreement between gamma and E-beam calibrations. The dosimeter is analyzed for its sensitivity, temperature and humidity dependencies, stability, reproducibility, and agreement of gamma and E-beam calibrations.
引用
收藏
页码:753 / 756
页数:4
相关论文
共 50 条
  • [31] Radiochromic film dosimetry: Past, present, and future
    Devic, Slobodan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (03): : 122 - 134
  • [32] Radiochromic Film Dosimetry and its Applications in Radiotherapy
    Williams, Matthew
    Metcalfe, Peter
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 75 - +
  • [33] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651
  • [34] Effect of Magnetic Field in Radiochromic Film Dosimetry
    Volotskova, O.
    Fang, X.
    Keidar, M.
    Chandarana, H.
    Das, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3136 - 3136
  • [35] Flatbed scanner stability for radiochromic film dosimetry
    Laosa, C.
    Calvo Ortega, J. F.
    Moragues Femenia, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S910 - S910
  • [36] RADIOCHROMIC FILM DOSIMETRY: COMPUTER CONTROLLED DENSITOMETER
    Sipila, P.
    Jarvinen, H.
    Jokelainen, I.
    Ojala, J.
    Niemela, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S476 - S476
  • [37] Noise in radiochromic film dosimetry with a CCD digitizer
    Gonzalez-Lopez, A
    Buades-Forner, M
    Quinones, L
    Arjona, J
    Tabarra-Gonzalez, J
    Torres-Donaire, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S143 - S144
  • [38] Optimizing the recalibration process in radiochromic film dosimetry
    Ruiz-Morales, Carmen
    Vera-Sanchez, Juan Antonio
    Gonzalez-Lopez, Antonio
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01):
  • [39] On the characterization and uncertainty analysis of radiochromic film dosimetry
    Bouchard, Hugo
    Lacroix, Frederic
    Beaudoin, Gilles
    Carrier, Jean-Francois
    Kawrakow, Iwan
    MEDICAL PHYSICS, 2009, 36 (06) : 1931 - 1946
  • [40] Computed tomography phantom for radiochromic film dosimetry
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Eguchi, M.
    Takewa, S.
    Tabuchi, A.
    Yatake, H.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (03) : 194 - 199