A THICKNESS INDEPENDENT RADIOCHROMIC FILM DOSIMETRY SYSTEM

被引:1
|
作者
RICKEY, JD
HUMPHERYS, KC
机构
[1] Far West Technology, Inc., Goleta, CA 93117
来源
RADIATION PHYSICS AND CHEMISTRY | 1993年 / 42卷 / 4-6期
关键词
ABSORBED DOSE; DOSIMETRY; ELECTRON BEAM; GAMMA-RADIATION; IONIZING RADIATION; QUALITY CONTROL; RADIATION PROCESSING; RADIOCHROMIC DOSIMETRY; RADIOCHROMIC FILM;
D O I
10.1016/0969-806X(93)90366-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new radiochromic thin film dosimeter has been developed for use in radiation processing. The dosimeter's properties are similar to diose of the commercially available FWT-60-00 Radiachromic Detectors with three key differences: 1) a lower sensitivity allows reading the optical density at the peak of the absorbtion spectrum (ca. 600 nm) for absorbed doses to over 50 kGy, 2) a radiation-insensitive dye additive allows for automatic thickness correction, and 3) another additive extends to higher doses the agreement between gamma and E-beam calibrations. The dosimeter is analyzed for its sensitivity, temperature and humidity dependencies, stability, reproducibility, and agreement of gamma and E-beam calibrations.
引用
收藏
页码:753 / 756
页数:4
相关论文
共 50 条
  • [1] EFFECTS OF SEVERAL PARAMETERS ON A THICKNESS-INDEPENDENT RADIOCHROMIC THIN-FILM DOSIMETRY SYSTEM
    RICKEY, JD
    HANDLOSER, JS
    WILDE, WO
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 1269 - 1272
  • [2] Effects of several parameters on a thickness-independent radiochromic thin-film dosimetry system
    Rickey, John D.
    Handloser, John S. Jr.
    Wilde, Waldo O.
    Radiation Physics and Chemistry, 1995, 46 (4-6 pt 1):
  • [3] Radiochromic film dosimetry
    Soares, Christopher G.
    RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [4] LINEARIZATION OF THE RADIOCHROMIC FILM DOSIMETRY SYSTEM DOSE RESPONSE
    Tomic, Nada
    Seuntjens, Jan
    DeBlois, Francois
    Devic, Slobodan
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S9 - S10
  • [5] Optimal response function for radiochromic film dosimetry system
    Devic, S.
    Aldelaijan, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [6] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [7] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603
  • [8] Linearization of Dose Response Curve for the Radiochromic Film Dosimetry System
    Lewis, D.
    Devic, S.
    Tomic, N.
    Aldelaijan, S.
    DeBlois, F.
    Chan, M.
    Seuntjens, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 4009 - 4009
  • [9] Feasibility study of an inexpensive densitometry system for radiochromic film dosimetry
    Jimenez-Aviles, Gerardo
    Camacho-Lopez, Miguel Angel
    Garcia-Garduno, Olivia Amanda
    Isaac-Olive, Keila
    MEASUREMENT, 2023, 211
  • [10] Optimizing the dynamic range extension of a radiochromic film dosimetry system
    Devic, Slobodan
    Tomic, Nada
    Soares, Christopher G.
    Podgorsak, Ervin B.
    MEDICAL PHYSICS, 2009, 36 (02) : 429 - 437