HIGH-VOLUME AIR SAMPLER FOR PARTICLE AND GAS SAMPLING .1. DESIGN AND GAS SAMPLING PERFORMANCE

被引:56
|
作者
HART, KM [1 ]
ISABELLE, LM [1 ]
PANKOW, JF [1 ]
机构
[1] OREGON GRAD INST,DEPT ENVIRONM SCI & ENGN,19600 NW VON NEUMANN DR,BEAVERTON,OR 97006
关键词
D O I
10.1021/es00029a027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high-volume air sampler was developed to collect organic compounds in the gas and particulate phases at flows up to 1.4 m3/min. Quartz fiber or Teflon membrane filters can be employed; use of a backup filter allows correction for the direct adsorption of gaseous analytes to the filter. Most of the filtered air passes through two 1.27 cm thick polyurethane foam sheets (PUFSa) in series; the remainder passes through two Tenax cartridges in series. The thin, filter-size (20 cm x 25 cm) PUFSs permit high-flow rates with minimal pressure drop. An adequate sample volume can be obtained in a minimum amount of time, minimizing the probability that atmospheric concentration fluctuations will cause volatilization losses from, or adsorption gains to particles on the filter. With sample volumes of 500-700 M3, at approximately 16-degrees-C, breakthrough from the first PUFS was < 30% for compounds less volatile than octadecane (C18) and phenanthrene. Good agreement was obtained for the compounds determined on both the PUFSs and the Tenax beds.
引用
收藏
页码:1048 / 1052
页数:5
相关论文
共 50 条
  • [21] Desorption of Herbicides from Atmospheric Particulates During High-Volume Air Sampling
    Cessna, Allan J.
    Waite, Don T.
    Bailey, Jonathan
    Kerr, Lorne A.
    Quiring, Dwight V.
    ATMOSPHERE, 2011, 2 (04): : 671 - 687
  • [22] MINIMAL VOLUME GAS SAMPLING VALVE
    BELL, TN
    HARRIS, KR
    WICK, FR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (12): : 1177 - 1178
  • [23] Next-generation ice-nucleating particle sampling on board aircraft: characterization of the High-volume flow aERosol particle filter sAmpler (HERA)
    Grawe, Sarah
    Jentzsch, Conrad
    Schaefer, Jonas
    Wex, Heike
    Mertes, Stephan
    Stratmann, Frank
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2023, 16 (19) : 4551 - 4570
  • [24] DESIGN OF A HIGH-VOLUME SAMPLER FOR AIRBORNE PESTICIDE COLLECTION
    COMPTON, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1972, : 21 - &
  • [25] Air sampling reveals high emissions from gas field
    Jeff Tollefson
    Nature, 2012, 482 : 139 - 140
  • [26] Air sampling reveals high emissions from gas field
    Tollefson, Jeff
    NATURE, 2012, 482 (7384) : 139 - 140
  • [27] FIELD EVALUATION OF HIGH-VOLUME PARTICLE FRACTIONATING CASCADE IMPACTOR - TECHNIQUE FOR RESPIRABLE SAMPLING
    BURTON, RM
    HOWARD, JN
    PENLEY, RL
    RAMSAY, PA
    CLARK, TA
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1973, 23 (04): : 277 - 281
  • [28] FORMATION OF NITROARENES DURING AMBIENT HIGH-VOLUME SAMPLING
    AREY, J
    ZIELINSKA, B
    ATKINSON, R
    WINER, AM
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (04) : 457 - 462
  • [29] HIGH-VOLUME IMPACTOR FOR SAMPLING FINE AND COARSE PARTICLES
    MARPLE, VA
    LIU, BYH
    BURTON, RM
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (05): : 762 - 767
  • [30] EVALUATION OF FILTERS FOR HIGH-VOLUME SAMPLING OF ATMOSPHERIC PARTICULATES
    KRAMER, DN
    MITCHEL, PW
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1967, 28 (03): : 224 - &