HIGH-VOLUME AIR SAMPLER FOR PARTICLE AND GAS SAMPLING .1. DESIGN AND GAS SAMPLING PERFORMANCE

被引:56
|
作者
HART, KM [1 ]
ISABELLE, LM [1 ]
PANKOW, JF [1 ]
机构
[1] OREGON GRAD INST,DEPT ENVIRONM SCI & ENGN,19600 NW VON NEUMANN DR,BEAVERTON,OR 97006
关键词
D O I
10.1021/es00029a027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high-volume air sampler was developed to collect organic compounds in the gas and particulate phases at flows up to 1.4 m3/min. Quartz fiber or Teflon membrane filters can be employed; use of a backup filter allows correction for the direct adsorption of gaseous analytes to the filter. Most of the filtered air passes through two 1.27 cm thick polyurethane foam sheets (PUFSa) in series; the remainder passes through two Tenax cartridges in series. The thin, filter-size (20 cm x 25 cm) PUFSs permit high-flow rates with minimal pressure drop. An adequate sample volume can be obtained in a minimum amount of time, minimizing the probability that atmospheric concentration fluctuations will cause volatilization losses from, or adsorption gains to particles on the filter. With sample volumes of 500-700 M3, at approximately 16-degrees-C, breakthrough from the first PUFS was < 30% for compounds less volatile than octadecane (C18) and phenanthrene. Good agreement was obtained for the compounds determined on both the PUFSs and the Tenax beds.
引用
下载
收藏
页码:1048 / 1052
页数:5
相关论文
共 50 条
  • [1] HIGH-VOLUME AIR SAMPLER FOR PARTICLE AND GAS SAMPLING .2. USE OF BACKUP FILTERS TO CORRECT FOR THE ADSORPTION OF GAS-PHASE POLYCYCLIC AROMATIC-HYDROCARBONS TO THE FRONT FILTER
    HART, KM
    PANKOW, JF
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (04) : 655 - 661
  • [2] Testing of high-volume sampler inlets for the sampling of atmospheric radionuclides
    Irshad, Hammad
    Su, Wei-Chung
    Cheng, Yung S.
    Medici, Fausto
    HEALTH PHYSICS, 2006, 91 (03): : 188 - 199
  • [3] Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler
    Madsen, A. M.
    Sharma, A. K.
    ANNALS OF OCCUPATIONAL HYGIENE, 2008, 52 (03): : 167 - 176
  • [4] CALIBRATION OF HIGH-VOLUME AIR SAMPLER
    LYNAM, DR
    PIERCE, JO
    CHOLAK, J
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (01): : 83 - &
  • [5] CALIBRATION OF HIGH-VOLUME AIR SAMPLER
    LYNAM, DR
    PIERCE, JO
    CHOLAK, J
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1968, 29 (02): : 86 - &
  • [6] High-volume sampler for size-selective sampling of bioaerosols including viruses
    Lim, Jun-Hyung
    Nam, Sang Hwan
    Kim, Jongwoo
    Kim, Nam Hoon
    Park, Gun-Soo
    Maeng, Jin-Soo
    Yook, Se-Jin
    ATMOSPHERIC ENVIRONMENT, 2021, 265
  • [7] HIGH-VOLUME AIR SAMPLING SYSTEM FOR USE WITH CELLULOSE FILTERS
    DAMS, R
    HEINDRYCKX, R
    ATMOSPHERIC ENVIRONMENT, 1973, 7 (03) : 319 - +
  • [8] PERSONAL AND HIGH-VOLUME AIR-SAMPLING CORRELATION PARTICULATES
    DUVALL, PM
    BOURKE, RC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1974, 8 (08) : 765 - 767
  • [9] ATMOSPHERIC AEROSOL SAMPLING BY AN ANNULAR DENUDER SYSTEM AND A HIGH-VOLUME PM(10) SAMPLER
    TSAI, CJ
    HUANG, HY
    ENVIRONMENT INTERNATIONAL, 1995, 21 (03) : 283 - 291
  • [10] Development of a high-volume air sampler for nanoparticles
    Hata, M.
    Thongyen, T.
    Bao, L.
    Hoshino, A.
    Otani, Y.
    Ikeda, T.
    Furuuchi, M.
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2013, 15 (02) : 454 - 462