Diagnostic Accuracy of NCCT Scan with DWI MRI Taking it as a Gold Standard in Detection of Acute Ischemic Stroke

被引:0
|
作者
Rasheed, Noreen [1 ]
Hamid, Saira [1 ]
Rani, Fouzia [1 ]
机构
[1] BV Hosp, Dept Radiol, Bahwalpur, Pakistan
来源
关键词
Acute ischemic stroke; diagnosis; NCCT Scan; DW MRI; diagnostic accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To determine the diagnostic accuracy of NCCT Scan with DWI MRI taking it as a gold standard in detection of acute ischemic stroke. Results: In this study, out of 237 cases, majority of the patients i.e., 59(24.89%) were between 31-50 years, mean and sd was calculated as 53.65 +/- 5.78 years, 132(55.70%) male and 105(44.30%) were females, frequency of acute ischemic stroke (on gold standard) reveals 68(28.69%), diagnostic accuracy of NCCT scan with DWI MRI taking it as a gold standard in detection of acute ischemic stroke, which shows 66(97.06%) true positive, 2(2.94%) had false positive, 165(97.63%) had true negative while 4(2.37%) had false negative, sensitivity, specificity, +ve predictive value, -ve predictive value and accuracy rate was computed as 97.06%, 97.63%, 94.29%, 98.80% and 97.47% respectively. Conclusion: Diagnostic accuracy of NCCT Scan when compared with DWI MRI (being gold standard) for the detection of acute ischemic stroke reveals significantly higher diagnostic accuracy.
引用
收藏
页码:635 / 637
页数:3
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Conventional MRI with Diffusion Weighted Imaging (DWI) in Detection of Cryptorchidism Taking Diagnostic Laparoscopy as Gold Standard
    Zahra, Mahwish
    Javed, Azhar Mehmood
    Noreen, Afshan
    Bushra, Hira
    Saeed, Umama
    Amin, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 471 - 474
  • [2] Diagnostic Accuracy of Transvaginal Ultrasound in Adenomyosis Taking MRI as a Gold Standard
    Shaikh, Afshan
    Masroor, Imrana
    Masood, Aysha
    Saeed, Shaista Afzal
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (10): : 1118 - 1123
  • [3] Diagnostic Accuracy of X-ray in Clinically Suspected Acute Sinusitis taking Computed Tomography Scan as Gold Standard
    Akhter, Muhammad Saleem
    Abbas, Muhammad Rafi
    Jamal, Yasir
    Rafique, Shahid
    Saleemi, Muhammad Yousaf
    Ali, Shahid
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (03): : 499 - 501
  • [4] Diagnostic Accuracy of Non Contrast CT Scan in Detection of Fungal Sinusitis by Taking Culture for Fungal Sinusitis as Gold Standard
    Rehman, Hafeez Ur
    Ali, Gulzar
    Sohu, Din Muhammad
    Sahito, Abid Ali
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 2098 - 2100
  • [5] Predictive Value of CT Brain Perfusion Studies in Acute Ischemic Infarct Taking MRI Stroke Protocol As Gold Standard
    Junejo, Hafeez-ur-Rehman
    Yusuf, Shazia
    Zeb, Romasa
    Zeb, Uswa
    Zeb, Ahmed A.
    Ali, Aamena
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (07)
  • [6] Determine the Diagnostic Accuracy of CT Scan for Diagnosing Nasal Septal Perforation Taking Histopathology as a Gold Standard
    Kakar, Abdul Latif
    Bazai, Rizwana Rehman
    Achakzai, Asmatullah
    Achakzai, Muhammad Arif
    Kakar, Jahan Zaib
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (04): : 759 - 761
  • [7] Diagnostic Accuracy of Ultrasound in Detection of Ureteric Calculi Taking CT KUB as Gold Standard
    Memon, Sasui
    Sahito, Abid Ali
    Suhail, Muhammad Ali
    Ashraf, Aiman
    Kumari, Sharni
    Ali, Kamran
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (04): : 1349 - 1351
  • [8] Diagnostic Accuracy of Ultrasonography for Detection of Achilles Tendinopathy by Taking Surgical Findings as Gold Standard
    Rafique, Iqra
    Manzoor, Anam
    Naseer, Sana
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (11): : 3093 - 3095
  • [9] DIAGNOSTIC ACCURACY OF MRI IN PREDICTING SOFT TISSUE MALIGNANCY OF MUSCULOSKELETAL SYSTEM BY TAKING HISTOPATHOLOGY AS GOLD STANDARD
    Saeeda
    Tahir, Mohammad
    Bukhari, Hassan
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (12): : 13802 - 13809
  • [10] Automated detection and volume measurement of acute ischemic stroke on DWI
    Phan, TG
    Wright, PM
    Indra, I
    Fitt, G
    Donnan, GA
    Reutens, DC