Diagnostic Accuracy of Ultrasound in Detection of Ureteric Calculi Taking CT KUB as Gold Standard

被引:0
|
作者
Memon, Sasui [1 ]
Sahito, Abid Ali [2 ]
Suhail, Muhammad Ali [3 ]
Ashraf, Aiman [4 ]
Kumari, Sharni [5 ]
Ali, Kamran [6 ]
机构
[1] LUMHS Jamshoro, BMC, Adv Diagnost Ctr, Radiol, Jamshoro, Pakistan
[2] LUMHS Jamshoro, Radiol Dept, Jamshoro, Pakistan
[3] Peoples Univ Med & Hlth Sci Women, Dept Urol, Nawabshah, Pakistan
[4] Sessi Kulsoombhai Valika Social Secur Site Hosp, Karachi, Pakistan
[5] PNS Shifa Karachi, Karachi, Pakistan
[6] CMH Hyderabad, Hyderabad, India
来源
关键词
Ureteric calculi; Ultrasound; sensitivity; specificity; PREDICT; STONES;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess the diagnostic accuracy of ultrasound in detection of ureteric calculi taking CT KUB as gold standard. Material and Method: Study design: Cross-sectional study. Setting: The study was conducted at Advance diagnostic Centre, Bilawal Medical College LUMHS Jamshoro Duration of study: Study duration was six months from April 2020 to September 2020. Methods: All the patients who were referred for CT KUB to diagnose the ureteric calculus, age more than 12 years and either of gender were included in this study. All the patients referred to CT KUB, underwent fresh transabdominal ultrasound after taking informed consent. All the data was recorded via self-made proforma. Data was analyzed by using SPSS version 20. 2X2 table was used to calculate the Sensitivity (SE), specificity (SP) "positive predictive value (PPV), negative predictive value (NPV) and accuracy of "trans abdominal ultrasound" by taking CT KUB as gold standard. Results: Mean age of total 60 cases was 36.6 +/- 8.49 years and mean duration of symptoms was 7.3 +/- 10.45 days. There were 51.7% males and 48.3% females. Ureteric calculi were detected among 68.3% of the cases on transabdominal ultrasound and 76.7% via CT KUB. Trans-abdominal ultrasound showed sensitivity 92% and specificity 44%, followed by positive predictive value (PPV) 90% and negative predictive value (NPP) 50% in the diagnosis of ureteric calculus by taking CT KUB as gold standard. Conclusion: Trans-abdominal ultrasonography was observed to be a safe, reliable, non-invasive, feasible and quick diagnostic tool to detect the ureteric calculus and severity of the obstruction.
引用
收藏
页码:1349 / 1351
页数:3
相关论文
共 50 条
  • [1] Diagnostic accuracy of Twinkling Artifact in detection of nephrolithiasis with CT-KUB as Gold Standard
    Arshad, Sumiya
    Ashraf, Rabia
    Farooq, Faiza
    RAWAL MEDICAL JOURNAL, 2021, 46 (04): : 830 - 833
  • [2] Diagnostic Accuracy of Transvaginal Ultrasound in Adenomyosis Taking MRI as a Gold Standard
    Shaikh, Afshan
    Masroor, Imrana
    Masood, Aysha
    Saeed, Shaista Afzal
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (10): : 1118 - 1123
  • [3] Diagnostic accuracy of ultrasound in the diagnosis of choledocholithiasis taking surgical findings as gold standard
    Hashmi, Fahad Mukhtar
    Jamil, Huma
    Anwar, Wajeeha
    Haidari, Farooque Ahmed
    Arshad, Farzeen
    Bashir, Zahid
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (04): : 1398 - 1400
  • [4] Diagnostic Accuracy of Doppler Ultrasound in the Diagnosis of Testicular Carcinoma by Taking Histopathology as Gold Standard
    Sahito, Abid Ali
    Ahsanullah
    Kumar, Vicky
    Hussain, Mohsim
    Ashraf, Humaira
    Jabeen, Humera
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (47A) : 447 - 451
  • [5] Diagnostic Accuracy of Ultrasound to Diagnose Intussusception in Children Taking Surgical Findings as Gold Standard
    Nazir, Nadia
    Amir, Irum
    Yousaf, Khalid Rehman
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (04): : 966 - 967
  • [6] Diagnostic Accuracy of Non Contrast CT Scan in Detection of Fungal Sinusitis by Taking Culture for Fungal Sinusitis as Gold Standard
    Rehman, Hafeez Ur
    Ali, Gulzar
    Sohu, Din Muhammad
    Sahito, Abid Ali
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 2098 - 2100
  • [7] Diagnostic Accuracy of Ultrasonography for Detection of Achilles Tendinopathy by Taking Surgical Findings as Gold Standard
    Rafique, Iqra
    Manzoor, Anam
    Naseer, Sana
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (11): : 3093 - 3095
  • [8] Diagnostic Accuracy of Chest Ultrasonography for Pneumothorax in Post Traumatic Patient taking CT as a gold standard
    Naseem, Ammara
    Hassan, Saba
    Ameer, Saima
    Bilal, Saira
    Haroon, Nighat
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (02): : 293 - 295
  • [9] Diagnostic Accuracy of Chest Ultrasonography for Pneumothorax in Post Traumatic Patient taking CT as a gold standard
    Naseem, Ammara
    Hassan, Saba
    Ameer, Saima
    Bilal, Saira
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 1985 - 1987
  • [10] Diagnostic Accuracy of Different Histological Stains for Helicobacter Pylori Detection, taking Immunohistochemistry as Gold Standard
    Gardezi, Atiya Batool
    Khan, Haseeb Ahmed
    Riaz, Sabiha
    Alam, Sadia
    Manzoor, Mariya
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 2676 - 2678