ESTABLISHMENT OF A SIMPLE NEUTRON CALIBRATION FIELD FROM A MODERATED CF-252 SOURCE .1. DESIGN AND CALCULATION OF THE SIMPLE NEUTRON CALIBRATION FIELD

被引:5
|
作者
HARA, A
IWAI, S
NAKAMURA, T
机构
[1] MITSUBISHI ATOM POWER IND INC,SAITAMA,JAPAN
[2] TOHOKU UNIV,CTR CYCLOTRON & RADIOISOTOPE,SENDAI,MIYAGI 980,JAPAN
关键词
D O I
10.1016/0168-9002(87)90497-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [31] Comparison of DD, DT and Cf-252 neutron excitation of light and medium mass nuclei for field PGNAA applications
    Seabury, E. H.
    Blackburn, B. W.
    Chichester, D. L.
    Wharton, C. J.
    Caffrey, A. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 839 - 844
  • [32] CALIBRATION OF VARIOUS TYPES OF NEUTRON DOSIMETERS IN A HEAVY-WATER MODERATED AND MONOENERGETIC NEUTRON FIELDS .1. THEORETICAL
    MATIULLAH
    KUDO, K
    YANG, X
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 683 - 686
  • [33] Measurement and calculation of the emission anisotropy of an X1 252cf neutron source
    Hawkes, N. P.
    Freedman, R.
    Tagziria, H.
    Thomas, D. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 78 - 82
  • [34] Evaluation of gamma contribution in a neutron calibration field of 241Am - Be source
    Thiem Ngoc Le
    Hoai-Nam Tran
    Thang Duc Duong
    Quynh Ngoc Nguyen
    Tuan Quang Ho
    Giap Van Trinh
    Khai Tuan Nguyen
    APPLIED RADIATION AND ISOTOPES, 2018, 133 : 117 - 120
  • [35] SIMPLE PULSED NEUTRON SOURCE BASED ON CROSSED-FIELD TRAPPING
    GOW, JD
    RUBY, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (05): : 315 - 317
  • [36] SPATIAL DISTRIBUTIONS OF THE EPITHERMAL NEUTRON-FLUX FROM A CF-252 SOURCE IN A BOREHOLE-FORMATION SYSTEM
    KHISAMUTDINOV, AI
    VORONIN, AF
    NUCLEAR GEOPHYSICS, 1990, 4 (04): : 437 - 441
  • [37] Photon contributions from the 252Cf and 241Am-Be neutron sources at the PSI Calibration Laboratory
    Hoedlmoser, H.
    Boschung, M.
    Meier, K.
    Stadtmann, H.
    Hranitzky, C.
    Figel, M.
    Mayer, S.
    RADIATION MEASUREMENTS, 2012, 47 (08) : 567 - 570
  • [38] FEASIBILITY OF REACTIVITY DETERMINATION FROM NEUTRON NOISE SPECTRAL DENSITY WITH CF-252 IN INITIAL LOADING OF LIGHT-WATER MODERATED REACTORS
    MIHALCZO, JT
    PARE, VK
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 (JUN): : 799 - 800
  • [39] Study the Possibility of Measuring Heavy Metals Arising from Gold Mining Sample using Cf-252 Neutron Source
    Soliman, N. F.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2012, 45 (03): : 206 - 211
  • [40] Characterization of a neutron calibration field with 241Am - Be source using Bonner sphere spectrometer
    Thiem Ngoc Le
    Hoai-Nam Tran
    Quynh Ngoc Nguyen
    Giap Van Trinh
    Khai Tuan Nguyen
    APPLIED RADIATION AND ISOTOPES, 2018, 133 : 68 - 74