Between 1969 and 1991, 339 patients had an aortic valve replacement with their own living pulmonary valve at the National Heart Hospital, Guy's Hospital and the Harley Street Clinic, London. The longest follow-up is 24 years and cumulative follow-up is 3774 patient-years. No form of anticoagulation was used and there were no emboli. There were 25 hospital deaths (7.4%) but only 1 death since 1976. Late deaths occurred in 38 patients mainly from technical mal-insertion. Bacterial endocarditis occurred in 11 patients. Thirty-eight patients were re-operated upon and account for 15 of the late deaths. Freedom from re-operation was 85% and the actuarial patient survival was 80% at 20 years. There has been no evidence of primary tissue degeneration and explanted valves showed normal cusp cellularity. Accumulating evidence suggests that the cusps not only survive permanently but can grow with the patient making the operation ideal for children.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 50 条
  • [41] PULMONARY AUTOGRAFT REPLACEMENT FOR SEVERE AORTIC VALVE DISEASE
    ROSS, DN
    RADLEYSM.R
    SOMERVILLE, J
    BRITISH HEART JOURNAL, 1969, 31 (06): : 797 - +
  • [42] Aortic valve malformations and pulmonary autograft root dilatation
    Fedak, PWM
    Verma, S
    Butany, J
    Weisel, RD
    David, TE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06): : 1222 - 1223
  • [43] AORTIC-VALVE RING ABSCESS SUBSEQUENT TO BACTERIAL-ENDOCARDITIS OF THE AORTIC-VALVE AND AORTIC-VALVE REPLACEMENT
    RUFFMANN, K
    SCHWARZ, F
    SAGGAU, W
    MOBIUS, H
    SCHMITZ, W
    OTTO, H
    KUBLER, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 (11): : 673 - 675
  • [44] AORTIC VALVE REPLACEMENT WITH A PULMONARY VALVE AUTOGRAFT - INDICATIONS AND SURGICAL TECHNIQUE
    GONZALEZLAVIN, L
    GEENS, M
    ROSS, D
    SURGERY, 1970, 68 (03) : 450 - +
  • [45] ECHOCARDIOGRAPHY OF AORTIC-VALVE - STUDIES OF NORMAL AORTIC-VALVE, AORTIC-STENOSIS, AORTIC REGURGITATION, AND MIXED AORTIC-VALVE DISEASE
    FEIZI, O
    SYMONS, C
    YACOUB, M
    BRITISH HEART JOURNAL, 1974, 36 (04): : 341 - 351
  • [46] Aortic valve replacement with a pulmonary autograft in infants with critical aortic stenosis
    Sudow, G
    Solymar, L
    Berggren, H
    Eriksson, B
    Holmgren, D
    Gilljam, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02): : 433 - 436
  • [47] Aortic root replacement with the pulmonary autograft:: An invariably competent aortic valve?
    Dossche, KM
    de la Riviére, AB
    Morshuis, WJ
    Schepens, MAAM
    Ernst, SM
    van den Brand, JJ
    ANNALS OF THORACIC SURGERY, 1999, 68 (04): : 1302 - 1307
  • [48] AORTIC-VALVE REPLACEMENT WITH ALLOGRAFT AUTOGRAFT - SUBCORONARY VERSUS INTRALUMINAL CYLINDER OR ROOT
    RUBAY, JE
    RAPHAEL, D
    SLUYSMANS, T
    VANOVERSCHELDE, JLJ
    ROBERT, A
    SCHOEVAERDTS, JC
    MARCHANDISE, B
    DION, RA
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S78 - S82
  • [49] EVALUATION OF AORTIC-VALVE SURGERY FOR ACQUIRED AORTIC-VALVE DISEASES
    CABROL, C
    GANDJBAKHCH, I
    PAVIE, A
    REVUE DU PRATICIEN, 1985, 35 (43): : 2599 - 2606
  • [50] FINE FLUTTERINGS OF AORTIC-VALVE AS DEMONSTRATED BY AORTIC-VALVE ECHOCARDIOGRAMS
    PINTO, ER
    DAMANI, PM
    STERNBERG, CN
    LIEDTKE, AJ
    AMERICAN HEART JOURNAL, 1978, 95 (06) : 807 - 808