THE PULMONARY AUTOGRAFT - A PERMANENT AORTIC-VALVE

被引:98
|
作者
ROSS, D [1 ]
JACKSON, M [1 ]
DAVIES, J [1 ]
机构
[1] INST CHILD HLTH,LIVERPOOL,ENGLAND
关键词
PULMONARY AUTOGRAFT; PULMONARY HOMOGRAFT;
D O I
10.1016/1010-7940(92)90115-E
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Between 1969 and 1991, 339 patients had an aortic valve replacement with their own living pulmonary valve at the National Heart Hospital, Guy's Hospital and the Harley Street Clinic, London. The longest follow-up is 24 years and cumulative follow-up is 3774 patient-years. No form of anticoagulation was used and there were no emboli. There were 25 hospital deaths (7.4%) but only 1 death since 1976. Late deaths occurred in 38 patients mainly from technical mal-insertion. Bacterial endocarditis occurred in 11 patients. Thirty-eight patients were re-operated upon and account for 15 of the late deaths. Freedom from re-operation was 85% and the actuarial patient survival was 80% at 20 years. There has been no evidence of primary tissue degeneration and explanted valves showed normal cusp cellularity. Accumulating evidence suggests that the cusps not only survive permanently but can grow with the patient making the operation ideal for children.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 50 条
  • [1] PULMONARY AUTOGRAFT REPLACEMENT OF THE AORTIC-VALVE
    WESTABY, S
    BRITISH HEART JOURNAL, 1995, 74 (01): : 1 - 3
  • [2] THE PULMONARY AUTOGRAFT AS AN AORTIC-VALVE REPLACEMENT
    TREASURE, T
    LANCET, 1994, 343 (8909): : 1308 - 1308
  • [3] PULMONARY AUTOGRAFT - THE OPTIMAL SUBSTITUTE FOR THE AORTIC-VALVE
    ELKINS, RC
    NEW ENGLAND JOURNAL OF MEDICINE, 1994, 330 (01): : 59 - 60
  • [4] PULMONARY AUTOGRAFT FOR AORTIC-VALVE REPLACEMENT IN CHILDREN
    LENTINI, S
    CARTIER, P
    METRAS, J
    CLOUTIER, A
    RAYMOND, G
    DESAULNIERS, D
    DOYLE, D
    LEMIEUX, M
    ANNALES DE CHIRURGIE, 1994, 48 (08): : 749 - 754
  • [5] REPLACEMENT OF THE AORTIC-VALVE WITH A PULMONARY AUTOGRAFT - THE SWITCH OPERATION
    ROSS, D
    ANNALS OF THORACIC SURGERY, 1991, 52 (06): : 1346 - 1350
  • [6] AORTIC-VALVE REPLACEMENT WITH PULMONARY AUTOGRAFT IN CHILDREN AND ADULTS
    CARTIER, PC
    METRAS, J
    CLOUTIER, A
    DUMESNIL, JG
    RAYMOND, G
    DOYLE, D
    DESAULNIERS, D
    LEMIEUX, MD
    LENTINI, S
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S177 - S179
  • [7] REPLACEMENT OF THE AORTIC-VALVE OR ROOT WITH A PULMONARY AUTOGRAFT IN CHILDREN
    GEROSA, G
    MCKAY, R
    ROSS, DN
    ANNALS OF THORACIC SURGERY, 1991, 51 (03): : 424 - 429
  • [8] PULMONARY AUTOGRAFT REPLACEMENT OF THE AORTIC-VALVE IN THE POTENTIAL PARENT
    ELKINS, RC
    KNOTTCRAIG, CJ
    RAZOOK, JD
    WARD, KE
    OVERHOLT, ED
    LANE, MM
    JOURNAL OF CARDIAC SURGERY, 1994, 9 (02) : 198 - 203
  • [9] PULMONARY AUTOGRAFT REPLACEMENT OF THE AORTIC-VALVE - AN EVOLUTION OF TECHNIQUE
    ELKINS, RC
    SANTANGELO, K
    STELZER, P
    RANDOLPH, JD
    KNOTTCRAIG, CJ
    JOURNAL OF CARDIAC SURGERY, 1992, 7 (02) : 108 - 116
  • [10] PULMONARY AUTOGRAFT FOR AORTIC-VALVE REPLACEMENT IN RHEUMATIC DISEASE - A CAVEAT
    ALHALEES, Z
    KUMAR, N
    GALLO, R
    GOMETZA, B
    DURAN, CMG
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S172 - S176