AMBULATORY ELECTROCARDIOGRAPHY (HOLTER MONITORING) IN CAGED MONKEYS

被引:4
|
作者
VOGEL, AP [1 ]
JAAX, GP [1 ]
TEZAKREID, TM [1 ]
BASKIN, SI [1 ]
BARTHOLOMEW, JL [1 ]
机构
[1] USA,MED RES INST CHEM DEF,DIV VET MED & LAB RESOURCES,ABERDEEN PROVING GROUND,MD 21010
关键词
AMBULATORY MONITORING; ELECTROCARDIOGRAPHY; MACACA SPECIES;
D O I
10.1258/002367791780808266
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A swivel-tethering and jacket system was used in conjunction with vinyl patch electrodes and Holter recorders to obtain continuous ECG recordings in 12 rhesus monkeys on a long-term (12 day) study. Animals were custom-fitted with nylon mesh jackets that were connected to a swivel unit by a flexible, stainless steel tether. Lead wires from the chest electrodes passed through the tether to the electrical swivel apparatus located at the top of the cage. Wires from the upper part of the swivel were attached to a reel-to-reel Holter recorder. This technique was used to obtain 24-h continuous ECG recordings, which were later processed using a computer-assisted Holter analysis system.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [41] ELECTROCARDIOGRAPHY BY TELEPHONE - AN ALTERNATIVE TO THE HOLTER SYSTEM
    SEGUI, FA
    TORRENT, MP
    JULINES, AV
    [J]. MEDICINA CLINICA, 1985, 84 (12): : 476 - 478
  • [42] Maximum QTc on Holter electrocardiography in children
    Ogawa, Yoshiharu
    Tanaka, Toshikatsu
    Kido, Sachiko
    [J]. PEDIATRICS INTERNATIONAL, 2018, 60 (06) : 507 - 512
  • [43] HOLTER DYNAMIC ELECTROCARDIOGRAPHY DURING LAPAROSCOPY
    CIMINO, L
    PETITTO, M
    NARDONE, G
    BUDILLON, G
    [J]. GASTROINTESTINAL ENDOSCOPY, 1988, 34 (01) : 72 - 72
  • [44] CLINICAL APPLICATION OF HOLTER CONTINUOUS ELECTROCARDIOGRAPHY
    BLEIFER, SB
    [J]. POSTGRADUATE MEDICAL JOURNAL, 1976, 52 : 60 - 66
  • [45] Design of a prototype for dynamic electrocardiography monitoring using GSM technology: GSM-Holter
    Guillen, JM
    Millet, J
    Cebrian, A
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3956 - 3959
  • [46] AMBULATORY BLOOD-PRESSURE AND HOLTER MONITORING DURING TENNIS PLAY
    JETTE, M
    LANDRY, F
    TIEMANN, B
    BLUMCHEN, G
    [J]. CANADIAN JOURNAL OF SPORT SCIENCES-REVUE CANADIENNE DES SCIENCES DU SPORT, 1991, 16 (01): : 40 - 44
  • [47] COMPUTER IDENTIFICATION OF VENTRICULAR ARRHYTHMIAS DETERMINANTS USING HOLTER AMBULATORY MONITORING
    MAISONBLANCHE, P
    MABO, P
    COUMEL, P
    SLAMA, R
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 994 - 994
  • [48] AMBULATORY ELECTROCARDIOGRAPHIC MONITORING (HOLTER) IN THE DIAGNOSTIC EVALUATION OF PATIENTS WITH NEUROLOGIC MANIFESTATIONS
    MORELL, JLA
    GUERRA, RR
    [J]. REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 1983, 35 (04): : 279 - 284
  • [49] Norman J. “Jeff” Holter–“Father” of Ambulatory ECG Monitoring
    S. Serge Barold
    [J]. Journal of Interventional Cardiac Electrophysiology, 2005, 14 : 117 - 118
  • [50] Onset mechanism of paroxysmal atrial fibrillation detected by ambulatory Holter monitoring
    Vincenti, A
    Brambilla, R
    Fumagalli, MG
    Merola, R
    Pedretti, S
    [J]. EUROPACE, 2006, 8 (03): : 204 - 210