Usefulness of implantable loop recorder in a patient with syncope during bathing

被引:4
|
作者
Nakao, Motohiro [1 ]
Kobayashi, Satoru [1 ]
机构
[1] Chibaken Saiseikai Narashino Hosp, Div Cardiol, 1-1-1 Izumicho, Narashino, Chiba 2758580, Japan
关键词
Neurally mediatedsyncope; Implantable loop recorder; Bathing; Sinus arrest;
D O I
10.1016/j.joa.2012.10.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 27-year-old man presented to our hospital with a 1-year-hisory of repeated syncope, which particularly occurred while bathing or on a hot day. The head-up tilt test did not induce arrhythmia; however, blood pressure decreased by 39 mm Hg without any symptoms. Given that no bradycardia/tachycardia was induced on electrophysiological study and carotid sinus massage, an implantable loop recorder (ILR) was implanted. After 2 months, syncope again occurred during bathing at midnight. Sinus arrest and a maximum ventricular pause of 10.2 s were documented using the ILR. After pacemaker implantation, the patient had not experienced syncope for 14 months. (C) 2012 Japanese Heart Rhythm Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 36
页数:3
相关论文
共 50 条
  • [21] Recurrent syncope of unknown origin: Diagnosis with an implantable loop recorder
    Sperzel, J
    Carlsson, J
    Erdogan, A
    Ehrlich, W
    Schulte, B
    Pitschner, HF
    Neuzner, J
    MEDIZINISCHE KLINIK, 2000, 95 (10) : 578 - 582
  • [22] Nonarrhythmic syncope documented by an implantable loop recorder (an ISSUE substudy)
    Brignole, M
    Menozzi, C
    Moya, A
    Garcia-Civera, R
    Donateo, P
    Puggioni, E
    Migliorini, R
    Navarro, X
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (06): : 654 - +
  • [23] Initial experience with an implantable loop recorder in patients with unexplained syncope
    Seidl, K
    Breunung, S
    Rameken, M
    Siemon, G
    Schwacke, H
    Drögemüller, A
    Zahn, R
    Senges, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 (01): : 43 - 50
  • [24] Implantable loop recorder is an effective diagnostic tool for unexplained syncope
    Bovin, Ann
    Malczynski, Jerzy
    Dalsgaard, Dorthe
    DANISH MEDICAL JOURNAL, 2012, 59 (10):
  • [25] Patients with recurrent syncope and implantable loop recorder exhibit better survival than the control group without implantable loop recorder
    Perings, C.
    Wolff, C.
    Wilk, A.
    Witthohn, A.
    Voss, R.
    Rybak, K.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3546 - 3546
  • [26] Data of the Belgian register on implantable loop recorder in unexplained syncope and stroke
    Barbraud, C.
    Rodriguez, J. Castro
    Verbeet, T.
    ACTA CARDIOLOGICA, 2011, 66 (05) : 669 - 670
  • [27] Diagnosis of a rare cause of arrhythmogenic syncope by means of an implantable loop recorder
    Berger, T
    Roithinger, FX
    Hintringer, F
    HEART, 2002, 88 (01) : 10 - 10
  • [28] Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope
    Santilli, Roberto A.
    Ferasin, Luca
    Voghera, Simona G.
    Perego, Manuela
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2010, 236 (01): : 78 - 82
  • [29] Catecholaminergic polymorphic ventricular tachycardia, recurrent syncope, and implantable loop recorder
    Hasdemir, C
    Priori, SG
    Overholt, E
    Lazzara, R
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 729 - 729
  • [30] Placebo effect of the implantable loop recorder in patients with recurrent neurocardiogenic syncope
    Antolinos, M. J.
    Lacunza, F. J.
    Garcia-Alberola, A.
    Cerdan, M. C.
    Sanchez, J. J.
    Martinez-Sanchez, J.
    Valdes, M.