CHARACTERIZATION OF DRUG DISPOSITION AND DOSING USING BIOELECTRICAL-IMPEDANCE

被引:0
|
作者
ZAROWITZ, BJ
PETERSON, EL
ROBERT, S
机构
[1] HENRY FORD HOSP, DEPT BIOSTAT, DETROIT, MI 48202 USA
[2] WAYNE STATE UNIV, COLL PHARM & ALLIED HLTH PROFESS, DETROIT, MI 48202 USA
关键词
BIOIMPEDANCE; DRUG; DOSING; GENTAMICIN; PHARMACOKINETICS; THEOPHYLLINE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioelectrical impedance analysis (BIA) yields accurate, safe and non-invasive estimates of body composition in humans. Pharmacokinetic characterization of drugs represents the body as a series of non-physiologic compartments. We evaluated the utility of BIA in the pharmacokinetic characterization and dosing of water soluble drugs. Serial serum concentrations of gentamicin (G) in 30 hospitalized adults, and theophylline (T), in 15 normal adult males were obtained over a dosing interval after an sh fast, and analyzed in duplicate by enzyme-mediated immunoassay technique. BIA was performed serially in duplicate during the same time period using a fixed frequency (50kHz, 8001 mu A) current-injection 4-electrode plethysmograph. Multiple regression techniques were used to develop descriptive models of pharmacokinetic parameters which yielded equations with p-values <0.03 and coefficients of variation <20% accounting for >85% of the pharmacokinetic variability. The G models were then tested in 20 critically ill adults at steady state by serum concentration measurement (criterion standard) and BIA. BIA predictive equations yielded pharmacokinetic parameters not different (by paired t-tests) than those derived by serum concentration measurement. While BIA is an innovative approach to the non-invasive characterization water soluble drugs, further testing with variable frequency BIA under perturbed conditions is warranted.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 50 条
  • [31] DETERMINATION OF TOTAL-BODY WATER IN UREMIC PATIENTS BY BIOELECTRICAL-IMPEDANCE
    KONG, CH
    THOMPSON, CM
    LEWIS, CA
    HILL, PD
    THOMPSON, FD
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1993, 8 (08) : 716 - 719
  • [32] BIOELECTRICAL-IMPEDANCE ASSESSMENT OF NUTRITIONAL-STATUS IN CRITICALLY ILL PATIENTS
    ROBERT, S
    ZAROWITZ, BJ
    HYZY, R
    EICHENHORN, M
    PETERSON, EL
    POPOVICH, J
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06): : 840 - 844
  • [33] A NEW BIOELECTRICAL-IMPEDANCE METHOD FOR MEASUREMENT OF THE ERYTHROCYTE SEDIMENTATION-RATE
    CHA, K
    BROWN, EF
    WILMORE, DW
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 (04) : 499 - 508
  • [34] BIVARIATE NORMAL VALUES OF THE BIOELECTRICAL-IMPEDANCE VECTOR IN ADULT AND ELDERLY POPULATIONS
    PICCOLI, A
    NIGRELLI, S
    CABERLOTTO, A
    BOTTAZZO, S
    ROSSI, B
    PILLON, L
    MAGGIORE, Q
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 269 - 270
  • [35] VALIDATION OF BIOELECTRICAL-IMPEDANCE MEASUREMENTS AS A METHOD TO ESTIMATE BODY-WATER COMPARTMENTS
    LICHTENBELT, WDV
    WESTERTERP, KR
    WOUTERS, L
    LUIJENDIJK, SCM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (02): : 159 - 166
  • [36] NUTRITIONAL ASSESSMENT (NA) USING BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) IN CHRONIC-HEMODIALYSIS (HD) PATIENTS
    CHERTOW, GM
    LOWRIE, EG
    WILMORE, DW
    GONZALEZ, J
    GOTTLIEB, MN
    LEBOFF, MS
    LEW, NL
    HUANG, W
    ZEBROWSKI, B
    COLLEGE, J
    LAZARUS, JM
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 489 - 489
  • [37] BIOELECTRICAL-IMPEDANCE ANALYSIS FOR ESTIMATING BODY-COMPOSITION OF SOWS IN-VIVO
    KRAETZL, WD
    THIELE, S
    TOMCZAK, J
    KAMPHUES, J
    ZUCHTUNGSKUNDE, 1995, 67 (02): : 132 - 146
  • [38] BIOELECTRICAL-IMPEDANCE ANALYSIS OF THE FAT-FREE MASS IN BREEDER TURKEY HENS
    GRIMES, JL
    ORT, JF
    CHRISTENSEN, VL
    BALL, HR
    POULTRY SCIENCE, 1990, 69 (03) : 369 - 377
  • [39] BIOELECTRICAL-IMPEDANCE ANALYSIS PREDICTS BODY-COMPOSITION IN PREGNANT-WOMEN
    ZEMEL, P
    KRAWCZYK, SL
    RAYNOR, H
    FASEB JOURNAL, 1994, 8 (04): : A182 - A182