Value of intra-operative ultrasound in localization of palpable or non-palpable breast tumors during breast conserving surgery

被引:0
|
作者
Abdelshafy, Shorouk Zaky Abdel Aziz [1 ,2 ]
Refaat, Medhat Mohamed [1 ,2 ]
Saleh, Gamal Elsayed [3 ]
Yousef, Mohammed, I [1 ,2 ]
机构
[1] Benha Univ, Dept Diagnost, Banha, Egypt
[2] Benha Univ, Dept Intervent Radiol, Banha, Egypt
[3] Benha Univ, Dept Gen Surg, Banha, Egypt
来源
关键词
Breast-conserving surgery (BCS); Intra-operative ultrasound (IOUS); Localization; Safety margins;
D O I
10.1016/j.ejrnm.2018.07.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our study was designed to assess the role of intra-operative ultrasound (IOUS) as a method of localization of palpable or non-palpable breast tumors during breast conserving surgery (BCS) and ensuring adequate margins by comparing pathological results of these lesions to be sure if the IOUS localization is effective as a localization tool or not. We included both palpable and non-palpable to add a great effect to the BCS to ensure adequate margins that are not accurately palpated by the surgeon. Introduction: Breast conserving surgery (BCS) is an alternative to mastectomy in treatment of cancer breast. The matter of tumor localization is a problematic issue with the wire localization being the commonest with multiple drawbacks. Another method for localization which is the IOUS is investigated. Patients and methods: This prospective, controlled study enrolled 60 female patients. 30 of them comprised case group (group I) had breast conserving surgeries guided by IOUS and the other 30 patients as a control (group II) who had breast conserving surgeries without any guidance. Specimens Pathological examination was done to ensure the adequacy of free margins. Results: 6 patients from the case group and 14 of the control group had involved inadequate margins. Conclusion: IOUS is an essential adjunct to surgery that should be experienced to maintain safety and cosmoses as the two major impacts of BCS.
引用
收藏
页码:1169 / 1174
页数:6
相关论文
共 50 条
  • [41] Intraoperative ultrasound is associated with low re-excision rates following breast conserving surgery for non-palpable invasive breast cancers
    Baliski, Christopher
    Jay, Michael
    Hamm, Jeremy
    [J]. AMERICAN JOURNAL OF SURGERY, 2021, 221 (06): : 1164 - 1166
  • [42] Intra-operative ultrasound in breast-conserving surgery for palpable breast cancer significantly improves both surgical accuracy and cosmetic outcome while saving costs.
    Haloua, M.
    Krekel, N.
    Coupe, V.
    van den Tol, P.
    Meijer, S.
    [J]. CANCER RESEARCH, 2012, 72
  • [43] WIRE LOCALIZATION OF NON-PALPABLE BREAST-LESIONS - REPLY
    HOMER, MJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (04) : 844 - 844
  • [44] Assessment of a new method for localization of non-palpable breast lesions
    Kaufman, Cary
    Lopez, January
    Cross, Michael
    Pierce, Kelly
    Lebovic, Gail
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : 521 - 522
  • [45] Image-guided Occult Lesion Localization for Non-Palpable Breast Cancer Tumors
    Orozco Cortes, J. R.
    Badenes Romero, A.
    Garrigos Ortega, G.
    Cueto Canadas, B.
    Latorre Agraz, I.
    Abreu, P.
    Mut, T.
    Balaguer, D.
    Vila, R.
    Pelaez, S.
    Caballero Calabuig, E.
    Plancha, M.
    Reyes, M.
    Martinez, R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S199 - S200
  • [46] Intra-operative Ultrasound is Imperative to Obtain Adequate Tumour Margins and Excision Volumes in Breast-conserving Surgery for Palpable Breast Cancer: Results of a Randomised Controlled Trial
    Krekel, N. M. A.
    Haloua, M. H.
    Cardozo, A. M. F. Lopes
    Bosch, A. M.
    Muller, S.
    de Widt, L.
    van Amerongen, A. H. M. Taets
    Bergers, E.
    Meijer, S.
    van den Tol, M. P.
    [J]. EUROPEAN JOURNAL OF CANCER, 2012, 48 : S2 - S2
  • [47] Optimising surgical accuracy in palpable breast cancer with intra-operative breast ultrasound - Feasibility and surgeons' learning curve
    Krekel, N. M. A.
    Cardozo, A. M. F. Lopes
    Muller, S.
    Bergers, E.
    Meijer, S.
    van den Tol, M. P.
    [J]. EJSO, 2011, 37 (12): : 1044 - 1050
  • [48] Intraoperative ultrasound is accurate for guiding breast conservative surgery in non-palpable ductal carcinoma in situ of the breast
    Esgueva, A.
    Regueira, F.
    Sagredo, N. Rodriguez-Spiteri
    Linaje, B. Olartecoechea
    Insausti, L. J. Pina
    Sampedro, C. Sobrido
    Perez, A. M. Elizalde
    Abengozar-Muela, M.
    Galan, T. Iscar
    Jimenez, M. J. Zubillaga
    Bacardi, A. Regojo
    De Bedoya, S. Fuente Martiez
    Rubio, I. T.
    [J]. EUROPEAN JOURNAL OF CANCER, 2022, 175 : S4 - S5
  • [49] The diagnostic accuracy of core biopsy in palpable and non-palpable breast lesions
    Pijnappel, RM
    vanDalen, A
    Rinkes, IHMB
    vandenTweel, JG
    Mali, WPTM
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (02) : 120 - 123
  • [50] Diagnostic value of needle-localization biopsy in the management of non-palpable breast lesions
    Shaikh, Aisha
    Fatima, Saira
    Shaikh, Sher Mohammad
    [J]. RAWAL MEDICAL JOURNAL, 2013, 37 (01): : 59 - 60