DETERMINATION OF LEAD IN GASOLINES BY DIFFERENTIAL PULSE POLAROGRAPHY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY

被引:0
|
作者
POLAK, J
机构
来源
CHEMICKE LISTY | 1991年 / 85卷 / 05期
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The article describes the determination of lead in gasolines by differential pulse polarography and differential pulse anodic stripping voltammetry. The method is based on the decomposition of tetraethyl-lead with a solution of ICl in acetic acid, elimination of the excess of iodine with a solution of styrene, extraction of lead with a 0.1 mol.l-1 HClO4 solution, conversion of the (C2H5)3Pb+ and (C2H5)2Pb2+ ions to Pb2+ ions on boiling, and subsequent measurement of the solution formed using the DPP technique, or, after elimination of the rest of the iodide ions, using the DPASV technique. The total duration of the analysis is 15-20 min in the first case and about 50-60 min in the second. The detection limit for the direct measurement of the extract with the DPP method is about 2 mg.l-1 of lead in the gasoline, and for the DPASV method it is 0.0001 mg.l-1.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 50 条
  • [41] Determination of lead and cadmium in titanium dioxide by differential pulse anodic stripping voltammetry
    Panigati, M
    Piccone, M
    D'Alfonso, G
    Orioli, M
    Carini, M
    [J]. TALANTA, 2002, 58 (03) : 481 - 488
  • [42] METAL SPECIATION IN POLYELECTROLYTIC SYSTEMS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    ESTEBAN, M
    DEJONG, HG
    VANLEEUWEN, HP
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) : 75 - 83
  • [43] APPLICATION OF PULSE POLAROGRAPHY WITH ANODIC-STRIPPING VOLTAMMETRY TO BIOLOGICAL AND TOXICOLOGICAL ANALYSES FOR LEAD AND CADMIUM
    HERBEUVAL, X
    MASO, JL
    BAUDOT, P
    HUTIN, MF
    BURNEL, D
    [J]. PATHOLOGIE BIOLOGIE, 1975, 23 (05): : 379 - 386
  • [44] A FLOW-THROUGH CELL FOR DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    MARTINS, EO
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1982, 140 (01) : 29 - 37
  • [45] SIMULTANEOUS DETERMINATION OF ZINC, CADMIUM AND LEAD IN MANGANESE SULFATE ELECTROLYTE BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    ADELOJU, SB
    TRAN, T
    [J]. ANALYST, 1986, 111 (12) : 1355 - 1358
  • [47] VERIFICATION OF LIVER DECOMPOSITION AND CADMIUM AND LEAD DETERMINATION BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY FROM INTERLABORATORY EXPERIMENT
    MADER, P
    KUCERA, J
    CIBULKA, J
    MIHOLOVA, D
    [J]. CHEMICKE LISTY, 1989, 83 (07): : 765 - 773
  • [48] DETERMINATION OF BACKGROUND LEVELS OF LEAD AND CADMIUM IN RAW AGRICULTURAL CROPS BY USING DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    SATZGER, RD
    CLOW, CS
    BONNIN, E
    FRICKE, FL
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1982, 65 (04): : 987 - 991
  • [49] DETERMINATION OF HEAVY-METALS IN CONCENTRATED REFINED SUGAR AND RAW SYRUPS WITH DIFFERENTIAL-PULSE POLAROGRAPHY AND ANODIC-STRIPPING VOLTAMMETRY
    KHOULIF, Z
    JAMBON, C
    CHATELUT, M
    VITTORI, O
    [J]. ELECTROANALYSIS, 1993, 5 (04) : 339 - 342
  • [50] Determination of Iodine Ion by Differential Pulse Anodic Stripping Voltammetry
    Tian, Yuan
    Song, Wen-Bo
    Jiang, Yan-Xia
    Liu, Ying
    Chen, Xu
    Xu, Hong-Ding
    [J]. Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 20 (01): : 30 - 31