EXPERIMENTAL 6 LOG10 WHITE CELL-REDUCTION FILTERS FOR RED-CELLS

被引:10
|
作者
SADOFF, BJ [1 ]
STROMBERG, RR [1 ]
MILLER, K [1 ]
NGO, D [1 ]
FRIEDMAN, LI [1 ]
机构
[1] AMER RED CROSS,JEROME H HOLLAND LAB BIOMED SCI,PROD DEV LAB,15601 CRABBS BRANCH WAY,ROCKVILLE,MD 20855
关键词
D O I
10.1046/j.1537-2995.1992.32292180140.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
White cell (WBC) reduction of blood components has been receiving increased attention as a way of reducing transfusion-related complications such as WBC-associated HLA alloimmunization and transmission of cell-associated viral diseases. Currently available filters are limited to removing approximately 3 log10 (99.9%) of WBCs from red cells (RBCs). The performance of two experimental filters that were designed to remove 6 log10 WBCs from fresh RBCs during component preparation was evaluated. Both filters were able to meet this objective in less than 40 minutes with RBC losses of < 15 percent under nonoptimized conditions. Filtered RBCs showed storage parameters within the normal range over a 42-day period. The use of these filters, if combined with a sterile docking device or if incorporated into a collection set, should provide the means to supply highly WBC-reduced RBCs with a normal shelf life.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 50 条
  • [31] CYTOKINE GENERATION IN STORED, WHITE CELL-REDUCED, AND BACTERIALLY CONTAMINATED UNITS OF RED-CELLS
    STACK, G
    BARIL, L
    NAPYCHANK, P
    SNYDER, EL
    TRANSFUSION, 1995, 35 (03) : 199 - 203
  • [32] Removal of anaphylatoxins C3a and C5a and chemokines interleukin 8 and RANTES by polyester white cell-reduction and plasma filters
    Geiger, TL
    Perrotta, PL
    Davenport, R
    Baril, L
    Snyder, EL
    TRANSFUSION, 1997, 37 (11-12) : 1156 - 1162
  • [33] USE OF WHITE CELL-REDUCED RED-CELLS FOR TRANSFUSION THROUGH PERIPHERAL ARTERIAL LINES
    DERLETH, DP
    TRANSFUSION, 1994, 34 (01) : 86 - 86
  • [34] EXPERIMENTAL ANIMAL-MODEL OF REFRACTORINESS TO DONOR PLATELETS - THE EFFECT OF PLASMA REMOVAL AND THE EXTENT OF WHITE CELL-REDUCTION ON ALLOGENEIC ALLOIMMUNIZATION
    BORDIN, JO
    BARDOSSY, L
    BLAJCHMAN, MA
    TRANSFUSION, 1993, 33 (10) : 798 - 801
  • [35] PREVENTION OF TRANSFUSION-ASSOCIATED CHAGAS-DISEASE - EFFICACY OF WHITE CELL-REDUCTION FILTERS IN REMOVING TRYPANOSOMA-CRUZI FROM INFECTED BLOOD
    MORAESSOUZA, H
    BORDIN, JO
    BARDOSSY, L
    MACPHERSON, DW
    BLAJCHMAN, MA
    TRANSFUSION, 1995, 35 (09) : 723 - 726
  • [36] VALIDATION OF A SIMPLE METHOD TO COUNT VERY LOW WHITE CELL CONCENTRATIONS IN FILTERED RED-CELLS OR PLATELETS
    MASSE, M
    NAEGELEN, C
    PELLEGRINI, N
    SEGIER, JM
    MARPAUX, N
    BEAUJEAN, F
    TRANSFUSION, 1992, 32 (06) : 565 - 571
  • [37] Optimal conditions for white cell reduction in red cells by filtration at the patient's bedside
    Sirchia, G
    Rebulla, P
    Sabbioneda, L
    Garcea, F
    Greppi, N
    TRANSFUSION, 1996, 36 (04) : 322 - 327
  • [38] Characterization of Packed Red Blood Cells Prepared with Experimental Multifunctional Leukocyte and Antibody-Reduction Filters
    Silliman, Christopher C.
    Kelher, Marguerite R.
    LaSarre, Monica
    Berry, Travis H.
    Schroeder, Kadi
    Le, Tuan
    Chaffin, D. Joe
    Land, Kevin J.
    Mish, Barbara
    Ceriano, Linda
    Sowemimo-Coker, Samuel O.
    BLOOD, 2011, 118 (21) : 1005 - 1006
  • [39] CHARACTERISTICS OF WHITE CELL-REDUCED RED-CELLS STORED IN TRI-(2-ETHYLHEXYL)TRIMELLITATE PLASTIC
    DAVEY, RJ
    HEATON, WAL
    SWEAT, LT
    STEC, NM
    NELSON, EJ
    HOLME, S
    TRANSFUSION, 1994, 34 (10) : 895 - 898
  • [40] USE OF GREATER-THAN-3 LOG LEUKOREDUCTION OF AS-3 RED-CELLS TO MINIMIZE THE RED-CELL STORAGE LESION IN NON-DEHP CONTAINERS
    HEATON, A
    HOLME, S
    SWEENEY, J
    NELSON, E
    TRANSFUSION, 1992, 32 (08) : S77 - S77