Short-term variation of central corneal thickness measurements in keratoconus using the Tono-Pachymeter NT530P (Tonopachy (TM))

被引:0
|
作者
Mashige, K. P. [1 ]
Oduntan, O. A. [1 ]
Gcabashe, N. M. [1 ]
机构
[1] Univ KwaZulu Natal, Sch Hlth Sci, Discipline Optometry, Westville Campus,Private Bag X54001, ZA-4000 Durban, South Africa
来源
AFRICAN VISION AND EYE HEALTH JOURNAL | 2012年 / 71卷 / 03期
关键词
Tonopachy (TM); central corneal thickness; keratoconus; repeatability; univariate normality;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Repeatability of values is a crucial reliability index in any instrument used to measure ocular parameters. The purpose of this study was to investigate short-term variability of central corneal thickness (CCT) measurements in keratoconic eyes. The Tono-Pachymeter NT530P (Tonopachy (TM)) was used to take fifty successive automatic measurements of CCT of the right eyes of ten keratoconic subjects (six females and four males), aged 19 to 41 years (mean = 30.4 +/- 6.8 years). The means, standard deviations and variances of the measurements showed little variation with good repeatability. The inter-subject or overall mean values and standard deviations of the measurements were 452.1 +/- 30.3 pm. The Kolmogorov-Smirnov (K-S), Lilliefors and Shapiro-Wilks (S-W) tests showed that generally the data was normally distributed, with a few exceptions. The results of this study suggest that over short periods of time, the Tonopachy (TM) provides repeatable measures of CCT in keratoconic corneas.
引用
收藏
页数:7
相关论文
共 7 条
  • [1] Short-term variation in central corneal thickness and in raocular pressure using the Tono-Pachymeter NT530P (Tonopachy (TM))
    Mashigea, K. P.
    Rampersad, N.
    Jhetam, S.
    Govender, P.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2012, 71 (01): : 12 - 21
  • [2] Reliability of the non-contact tono-pachymeter Tonopachy NT-530P in healthy eyes
    Garcia-Resua, Carlos
    Pena-Verdeal, Hugo
    Minones, Mercedes
    Jesus Giraldez, M.
    Yebra-Pimentel, Eva
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (03) : 286 - 294
  • [3] Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure
    Fujimura, Fusako
    Kamiya, Kazutaka
    Fujiwara, Kazuko
    Shoji, Nobuyuki
    Shimizu, Kimiya
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [4] A comparison of intraocular pressure values obtained with the Tono-Pachymeter NT530P iCare (R) rebound tonometer and Goldmann applanation tonometer
    Rampersad, N.
    Mashige, K. P.
    Jhetamt, S.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2011, 70 (03):
  • [5] Comparison of central corneal thickness using non-contact tono-pachymeter (Tonopachy) with ultrasound pachymetry in normal children and in children with refractive error
    Thiagarajan, Kiruthikadevi
    Srinivasan, Kavitha
    Gayam, Keerthi
    Rengaraj, Venkatesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (08) : 2053 - 2059
  • [6] Short-term variation of central corneal thickness and axial anterior chamber depth of healthy eyes using Scheimpflug photography via the Oculus Pentacam
    Mathebula, S. D.
    Rubin, A.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2009, 68 (01): : 12 - 24
  • [7] Correlation of central corneal thickness measurements using Topcon TRK-1P, Zeiss Visante AS-OCT and DGH Pachmate 55 handheld ultrasonic pachymeter
    Wells, Matthew
    Wu, Nerida
    Kokkinakis, Jim
    Sutton, Gerard
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (04) : 385 - 387