HIGH-ENERGY ELECTRON-PHOTON DETECTOR WITH GOOD SPATIAL-RESOLUTION USING ANALOG READOUT MULTIWIRE PROPORTIONAL CHAMBERS

被引:14
|
作者
GABATHULER, E [1 ]
OSBORNE, AM [1 ]
CLIFFT, RW [1 ]
SPROSTON, M [1 ]
机构
[1] RUTHERFORD LAB,OXFORD,ENGLAND
来源
NUCLEAR INSTRUMENTS & METHODS | 1978年 / 157卷 / 01期
关键词
D O I
10.1016/0029-554X(78)90586-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [41] High-energy resolution spectrometer with proportional counter and Si-detector telescope type for 14 MeV neutrons in plasma diagnostics
    Mori, C
    Gotoh, J
    Uritani, A
    Miyahara, H
    Ikeda, Y
    Kasugai, Y
    Kaneko, J
    Sasao, M
    Sakuma, Y
    Kudo, K
    Takeda, N
    Iida, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 75 - 78
  • [42] Comparison of reflection high-energy electron diffraction and low-energy electron diffraction using high-resolution instrumentation
    Muller, B
    Henzler, M
    SURFACE SCIENCE, 1997, 389 (1-3) : 338 - 348
  • [43] SPATIAL PATTERN-RECOGNITION IN A HIGH-ENERGY PARTICLE DETECTOR USING A NEURAL NETWORK ALGORITHM
    DENBY, B
    LINN, SL
    COMPUTER PHYSICS COMMUNICATIONS, 1990, 56 (03) : 293 - 297
  • [44] ACCURATE MICROCRYSTALLOGRAPHY AT HIGH SPATIAL-RESOLUTION USING ELECTRON BACKSCATTERING PATTERNS IN A FIELD-EMISSION GUN SCANNING ELECTRON-MICROSCOPE
    HARLAND, CJ
    AKHTER, P
    VENABLES, JA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (02): : 175 - 182
  • [45] REALIZATION OF HIGH-ENERGY RESOLUTION USING HEMISPHERICAL ELECTROSTATIC ENERGY SELECTOR IN ELECTRON-IMPACT SPECTROMETRY
    BRUNT, JNH
    READ, FH
    KING, GC
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1977, 10 (02): : 134 - 139
  • [46] Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector
    Clements, N.
    Richtsmeier, D.
    Hart, A.
    Bazalova-Carter, M.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01)
  • [47] Super high resolution measurement of total photonuclear cross sections using laser compton photons and a high-resolution high-energy photon spectrometer
    Harada, H
    Furutaka, K
    Shigetome, Y
    Ohgaki, H
    Toyokawa, H
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2000, 529 : 722 - 724
  • [48] A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams
    Banjade, DP
    Tajuddin, AA
    Shukri, A
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (03) : 297 - 302
  • [49] Improved accuracy in radiotherapy dosimetry of high-energy photon and electron beam using optically stimulated luminescence
    Yukihara, E.
    Mardirossian, G.
    Mirzasadeghi, M.
    Guduru, S.
    Ahmad, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2458 - 2458
  • [50] Portal verification of high-energy electron beams using their photon contamination by film-cassette systems
    Geyer, P
    Baus, WW
    Baumann, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 (01) : 37 - 44