IN-VIVO DETERMINATION OF THE ACCURACY OF FIELD MATCHING IN BREAST-CANCER IRRADIATION USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:25
|
作者
HOLMBERG, O
HUIZENGA, H
IDZES, MHM
LEBESQUE, JV
VIJLBRIEF, RE
MIJNHEER, BJ
机构
[1] ANTONI VAN LEEUWENHOEK HUIS,NETHERLANDS CANC INST,DEPT RADIOTHERAPY,1066 CX AMSTERDAM,NETHERLANDS
[2] DR DANIEL DEN HOED CANC CTR,3008 AE ROTTERDAM,NETHERLANDS
关键词
FIELD MATCHING; ACCURACY; PORTAL IMAGING; QUALITY ASSURANCE; BREAST CANCER;
D O I
10.1016/0167-8140(94)90070-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to investigate the accuracy of field matching in patients treated by irradiation of the breast and adjacent lymph nodes. Field matching is performed by the radiographers during each session on a match line drawn on the patient's skin, Field edge positions were assessed in the cranial match plane of tangential breast fields and supraclavicular-axillary fields using an electronic portal imaging device and match line markers placed on the skin of the patients. The mean gap/overlap of the four fields for individual patients during each treatment session, derived from 374 marker projections, was +0.5 mm indicating that no systematic gap or overlap was observed, The uncertainty in the position of the four fields with respect to the match plane ranges from 3.1 to 5.1 mm (1 SD) for the individual patients, Gaps and overlaps between fields were also related to an absolute match line position, found by comparison of simulator and portal images, showing a small systematic uncertainty of 2.4 mm and a standard deviation of 3.3 mm, It can be concluded that the use of an electronic portal imaging device in combination with match line markers is a good method to quantify the accuracy of field matching in vivo. The results showed good stability and reproducibility in the field matching region for this treatment technique of breast cancer irradiation.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [41] Assessment of Multi-leaf Collimator Positional Accuracy Using Radiochromic EBT3 Film and an Electronic Portal Imaging Device
    Forough Nikeghbali
    Abolfazl Nickfarjam
    Fateme Shirani
    Nouraddin Abdi Goushbolagh
    Nasim Namiranian
    Bagher Farhood
    Masoud Shabani
    Kazem Vakili
    [J]. Journal of the Korean Physical Society, 2020, 76 : 795 - 801
  • [42] Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Koizumi, Masahiko
    Ogata, Toshiyuki
    Takahashi, Yutaka
    Yoshioka, Yasuo
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (05) : 798 - 806
  • [43] Evaluation of Setup Uncertainties for Electron Boost Field Treated Using Compression Device for Breast Cancer Irradiation
    Wang, X.
    Salehpour, M.
    Howell, R.
    Melancon, A.
    Sun, T.
    Woodward, W.
    Smith, B.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Assessment of Multi-leaf Collimator Positional Accuracy Using Radiochromic EBT3 Film and an Electronic Portal Imaging Device
    Nikeghbali, Forough
    Nickfarjam, Abolfazl
    Shirani, Fateme
    Goushbolagh, Nouraddin Abdi
    Namiranian, Nasim
    Farhood, Bagher
    Shabani, Masoud
    Vakili, Kazem
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (09) : 795 - 801
  • [45] The experience of a developing country using an electronic portal imaging device for the verification of patient positioning and dosimetry in radiotherapy for prostate cancer
    Farhat, Leila
    Fourati, N.
    Mnejja, W.
    Daoud, J.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (03) : 297 - 301
  • [46] Determination Off-Axis Dosimetric Leaf Gap Using Optically Stimulated Luminescence Dosimeters and An Electronic Portal Imaging Device
    Santosh, T. P. B.
    Divyalakshmi, J.
    Rafic, K. M. Mohamathu
    Sebastin, A.
    Christopher, J. Sujith
    Raj, J. S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E740 - E740
  • [47] Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device
    Yoon, J.
    Jung, J.
    Yi, B.
    Kim, J.
    Yeo, I.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3667 - 3667
  • [48] A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)
    Herchko, S.
    Ding, G.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3575 - 3575
  • [49] Daily MV Portal Imaging with 2D Matching of Supraclavicular Fields Improves Conformal Radiotherapy Setup Accuracy for Multiple Field Breast Treatments
    O'Leary, K.
    Clancy, P.
    Sroczinski, L.
    Kachnic, L.
    Qureshi, M.
    Hirsch, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S242 - S243
  • [50] Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery
    Balasingh, S. Timothy Peace
    Singh, I. Rabi Raja
    Rafic, K. Mohamathu
    Babu, S. Ebenezer Suman
    Ravindran, B. Paul
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (03) : 129 - 135