IN-VIVO DETERMINATION OF THE ACCURACY OF FIELD MATCHING IN BREAST-CANCER IRRADIATION USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:25
|
作者
HOLMBERG, O
HUIZENGA, H
IDZES, MHM
LEBESQUE, JV
VIJLBRIEF, RE
MIJNHEER, BJ
机构
[1] ANTONI VAN LEEUWENHOEK HUIS,NETHERLANDS CANC INST,DEPT RADIOTHERAPY,1066 CX AMSTERDAM,NETHERLANDS
[2] DR DANIEL DEN HOED CANC CTR,3008 AE ROTTERDAM,NETHERLANDS
关键词
FIELD MATCHING; ACCURACY; PORTAL IMAGING; QUALITY ASSURANCE; BREAST CANCER;
D O I
10.1016/0167-8140(94)90070-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to investigate the accuracy of field matching in patients treated by irradiation of the breast and adjacent lymph nodes. Field matching is performed by the radiographers during each session on a match line drawn on the patient's skin, Field edge positions were assessed in the cranial match plane of tangential breast fields and supraclavicular-axillary fields using an electronic portal imaging device and match line markers placed on the skin of the patients. The mean gap/overlap of the four fields for individual patients during each treatment session, derived from 374 marker projections, was +0.5 mm indicating that no systematic gap or overlap was observed, The uncertainty in the position of the four fields with respect to the match plane ranges from 3.1 to 5.1 mm (1 SD) for the individual patients, Gaps and overlaps between fields were also related to an absolute match line position, found by comparison of simulator and portal images, showing a small systematic uncertainty of 2.4 mm and a standard deviation of 3.3 mm, It can be concluded that the use of an electronic portal imaging device in combination with match line markers is a good method to quantify the accuracy of field matching in vivo. The results showed good stability and reproducibility in the field matching region for this treatment technique of breast cancer irradiation.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [1] QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER
    CREUTZBERG, CL
    ALTHOF, VGM
    HUIZENGA, H
    VISSER, AG
    LEVENDAG, PC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 529 - 539
  • [2] Assement of the accuracy of treatment fields with electronic portal imaging device (EPID) in a breast irradiation
    Cetinayak, H. O.
    Gorken, I.
    Eyiler, F.
    Dag, N.
    Bayraktar, F.
    Sengunay, F.
    Yigitbasi, L.
    Ates, L.
    Alanyali, H.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S278 - S279
  • [3] Development and clinical implementation of in-vivo dosimetry using an electronic portal imaging device
    Kroonwijk, M
    Pasma, KL
    Quint, S
    Visser, AG
    Heijmen, BJM
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 276 - 278
  • [4] Commissioning of An In-Vivo Quality Assurance Method Using the Electronic Portal Imaging Device
    Morin, O.
    Held, M.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 326 - 327
  • [5] ESTROGEN-RECEPTOR DETERMINATION IN-VIVO IN BREAST-CANCER
    SCHARL, A
    SCHEIDHAUER, K
    GOHRING, UJ
    BECKMANN, MW
    SMOLARZ, K
    HOLT, JA
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1993, 254 (1-4) : 777 - 778
  • [6] Quality assurance using portal imaging: The accuracy of patient positioning in irradiation of breast cancer
    Pradier, O
    Bouscayrol, H
    [J]. EUROPEAN JOURNAL OF CANCER, 1995, 31A : 176 - 176
  • [7] In vivo dosimetry with electronic portal imaging device in VMAT for prostate cancer
    Inui, S.
    Ueda, Y.
    Ono, S.
    Ohira, S.
    Isono, M.
    Nitta, Y.
    Murata, S.
    Miyazaki, M.
    Teshima, T.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S942 - S942
  • [8] In-vivo dosimetry, using electronic portal imaging and Monte Carlo techniques
    Jarry, G.
    Verhaegen, F.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2167 - 2167
  • [9] Small field measurements using electronic portal imaging device
    Sait, A. Aziz
    Yoganathan, S. A.
    Jones, Glenn W.
    Patel, Tusar
    Rastogi, Nikhil
    Pandey, S. P.
    Mani, Sunil
    Boopathy, Raghavendiran
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):
  • [10] Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software
    Held, Mareike
    Cheung, Joey
    Andujar, Angelica Perez
    Husson, Francois
    Morin, Olivier
    [J]. CUREUS, 2018, 10 (02):