Sleep in Mechanically Ventilated Patients in the Intensive Care Unit
被引:2
|
作者:
Ersoy, Ebru Ortac
论文数: 0引用数: 0
h-index: 0
机构:
Hacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, TurkeyHacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, Turkey
Ersoy, Ebru Ortac
[1
]
论文数: 引用数:
h-index:
机构:
Ocal, Serpil
[1
]
Kara, Atila
论文数: 0引用数: 0
h-index: 0
机构:
Hacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, TurkeyHacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, Turkey
Kara, Atila
[1
]
Ardic, Sadik
论文数: 0引用数: 0
h-index: 0
机构:
Kafkas Univ, Fac Med, Dept Chest Dis, Kars, TurkeyHacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, Turkey
Ardic, Sadik
[2
]
Topeli, Arzu
论文数: 0引用数: 0
h-index: 0
机构:
Hacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, TurkeyHacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, Turkey
Topeli, Arzu
[1
]
机构:
[1] Hacettepe Univ, Fac Med, Dept Internal Med, Intens Care Unit, Ankara, Turkey
[2] Kafkas Univ, Fac Med, Dept Chest Dis, Kars, Turkey
Objective: Sleep abnormalities are common in critically ill patients. Polysomnography (PSG) is the gold standard in assessing sleep quality. The aim of this prospective study was to monitor the sleep pattern in mechanically ventilated patients with PSG who were admitted to our medical intensive care unit. Materials and Methods: This study was conducted in the Medical Intensive Care Unit of an University Hospital. Patients with endotracheal intubation and mechanical ventilation for at least 24 hours were included in the study. They were monitored for 18 hours per day by continuous PSG. Sleep parameters were recorded; [total sleep time (TST), sleep efficiency (SE) and sleep stages]. Results: Records of 12 patients were evaluated. There were nine males and three females. Median age of patients were 72.5 years (minmax=31-92). Median APACHE II was 19 (min-max=10-27). Median sleep time was 489.5 minutes (180-1105), median SE was 77.1% (24.9-96.5) and median arousal number was 147.5/TST (14-450). While REM sleep and non REM stage 3 sleep time and proportion were found to be decreased, non REM stage 2 sleep time and proportion were increased. Conclusion: We have shown that mechanically ventilated patients have changes in sleep architecture and that they have severe sleep fragmentation. Future research should address the cause of these problems by using methodology for comprehensive assessment of sleep-disrupting factors and by examining the dynamic effects of changes in illness severity on sleep quality.
机构:
INOVA Loudoun Hosp, Leesburg, VA USAINOVA Loudoun Hosp, Leesburg, VA USA
Lee, Cindy K.
Tefera, Eshetu
论文数: 0引用数: 0
h-index: 0
机构:
George Washington Univ, Sch Med, MedStar Hlth Res Inst, Washington, DC USAINOVA Loudoun Hosp, Leesburg, VA USA
Tefera, Eshetu
Colice, Gene
论文数: 0引用数: 0
h-index: 0
机构:
George Washington Univ, Sch Med, Washington Hosp Ctr, Washington, DC USA
George Washington Univ, Sch Med, Washington, DC USAINOVA Loudoun Hosp, Leesburg, VA USA
机构:
North China Univ Sci & Technol, Dept Crit Care Med, Affiliated Hosp, Tangshan 063000, Peoples R ChinaCapital Med Univ, Fuxing Hosp, Dept Crit Care Med, Beijing 100038, Peoples R China
Wang, Y. H.
Xi, Xiuming
论文数: 0引用数: 0
h-index: 0
机构:
Capital Med Univ, Fuxing Hosp, Dept Crit Care Med, Beijing 100038, Peoples R ChinaCapital Med Univ, Fuxing Hosp, Dept Crit Care Med, Beijing 100038, Peoples R China
机构:
Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld 4032, Australia
Univ Queensland, Sch Med, Brisbane, Qld, AustraliaPrince Charles Hosp, Crit Care Res Grp, Brisbane, Qld 4032, Australia