Fracture resistance and survival of implant-supported, zirconia-based hybrid-abutment crowns: Influence of aging and crown structure

被引:17
|
作者
Elshiyab, Shareen H. [1 ,2 ]
Nawafleh, Noor [2 ]
Walsh, Laurence [3 ]
George, Roy [1 ]
机构
[1] Griffith Univ, Sch Dent & Oral Hlth, Gold Coast, Australia
[2] Jordan Univ Sci & Technol, Dept Appl Dent Sci, Fac Appl Med Sci, Irbid, Jordan
[3] Univ Queensland, Sch Dent, Brisbane, Qld, Australia
关键词
aging; crown; hybrid abutment; monolithic crown; zirconia;
D O I
10.1111/jicd.12355
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of the present study was to investigate fracture resistance of implant-supported zirconia-based crowns (monolayer vs bilayer) cemented to hybrid abutments. Methods Monolayer and bilayer zirconia crowns were constructed and cemented to zirconia hybrid abutments. Crowns were divided into two subgroups: (a) untreated control group; and (b) experimental group, which underwent thermal-cycling mechanical loading in a chewing simulator. Up to 1.2 million stress cycles with simultaneous thermocycling (5 and 55 degrees C) were applied. Samples were finally subjected to static load to fracture. Data were analyzed using one-way analysis of variance and t test. Fractured surfaces were observed using scanning electron microscopy. Results Monolayer zirconia crowns had a 100% survival rate upon completion of the thermal mechanical loading, whereas bilayer zirconia crowns had a 50% survival rate. The fracture load of monolayer zirconia crowns was significantly higher than that of bilayer crowns. Moreover, the fracture load was significantly reduced in monolayer zirconia crowns after aging. Monolayer zirconia crowns showed bulk fracture within the monolayer, while bilayer crowns exhibited cohesive fracture within the veneering porcelain only. Conclusions Monolayer implant-supported hybrid-abutment crowns exhibit significantly higher fracture resistance compared to bilayer crowns, making them better suited to handle higher masticatory loads encountered in the posterior region of the mouth.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Fracture resistance of zirconia-based implant abutments after artificial long-term aging
    Alsahhaf, Abdulaziz
    Spies, Benedikt Christopher
    Vach, Kirstin
    Kohal, Ralf-Joachim
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 66 : 224 - 232
  • [32] Clinical outcomes of zirconia-based implant- and tooth-supported single crowns
    Farahnaz Nejatidanesh
    Hedayat Moradpoor
    Omid Savabi
    Clinical Oral Investigations, 2016, 20 : 169 - 178
  • [33] An In Vitro Investigation of the Role of Implant Abutment Materials on the Fracture Resistance and Failure Mode of Implant-Supported Restorations
    Obulareddy, Vishnu Teja
    Dixit, Arti
    Takhellambam, Violeta
    Verma, Rajnish K.
    Deepyanti
    Kumar, Sandeep
    Kumar, Amit
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [34] The influence of titanium-base abutment geometry and height on mechanical stability of implant-supported single crowns
    Karasan, Duygu
    Pitta, Joao
    Zarauz, Cristina
    Strasding, Malin
    Liu, Xinran
    Fehmer, Vincent
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 1033 - 1041
  • [35] Impact of Coping Veneering Techniques on the Survival of Implant-Supported Zirconia-Based-Crowns Cemented to Hybrid-Abutments: An-In-Vitro Study
    Elshiyab, Shareen Hayel
    Nawafleh, Noor
    Khan, Usman
    Ochsner, Andreas
    George, Roy
    BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 14
  • [36] Effect of framework design on fracture load after thermal cycling and mechanical loading of implant-supported zirconia-based prostheses
    Komine, Futoshi
    Kamio, Shingo
    Takata, Hiroki
    Yagawa, Shogo
    Taguchi, Serina
    Taguchi, Kohei
    Hashiguchi, Akiko
    Matsumura, Hideo
    DENTAL MATERIALS JOURNAL, 2018, 37 (01) : 78 - 86
  • [37] In Vitro Shock Absorption Tests on Implant-Supported Crowns: Influence of Crown Materials and Luting Agents
    Rosentritt, Martin
    Schneider-Feyrer, Sibylle
    Behr, Michael
    Preis, Verena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 116 - 122
  • [38] Effect of screw access hole on the fracture load of implant-supported monolithic zirconia single crown
    Zhang, Shusen
    Cheng, Qi
    Wei, Min
    Zhu, Yuanjing
    Han, Yu
    Chen, Yu
    Wang, Ran
    Chen, Chengxin
    Zhou, Hongbo
    ADVANCES IN APPLIED CERAMICS, 2022, 121 (01) : 1 - 11
  • [39] Influence of ceramic crown design (translucent monolithic zirconia vs. bilayered) of implant-supported single crowns after mechanical cycling
    Limirio, Joao Pedro Justino de Oliveira
    Gomes, Jessica Marcela de Luna
    Santiago-Junior, Joel Ferreira
    Nagay, Bruna Egumi
    Pesqueira, Aldieris Alves
    Assuncao, Wirley Goncalves
    Alves-Rezende, Maria Cristina Rosifini
    Pellizzer, Eduardo Piza
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (09) : 1326 - 1336
  • [40] Network meta-analysis of survival rate and complications in implant-supported single crowns with different abutment materials
    Hu, Menglong
    Chen, Junyu
    Pei, Xibo
    Han, Jianmin
    Wang, Jian
    JOURNAL OF DENTISTRY, 2019, 88