INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT

被引:273
|
作者
COLEMAN, AL
HILL, R
WILSON, MR
CHOPLIN, N
KOTASNEUMANN, R
TAM, M
BACHARACH, J
PANEK, WC
机构
[1] UNIV CALIF IRVINE,SCH MED,DEPT OPHTHALMOL,IRVINE,CA 92717
[2] USN,MED CTR,SAN DIEGO,CA 92152
[3] CHAIM SHEBA MED CTR,GOLDSCHLEGER EYE INST,IL-52621 TEL HASHOMER,ISRAEL
[4] CALIF PACIFIC MED CTR,SAN FRANCISCO,CA
[5] VET ADM OUTPATIENT CLIN,SACRAMENTO,CA
关键词
D O I
10.1016/S0002-9394(14)73755-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: We studied the Ahmed Glaucoma Valve implant, an aqueous shunting device that has a unidirectional valve mechanism designed to prevent postoperative hypotony in eyes with in tractable glaucoma. METHODS: In this multicenter, prospective clinical trial, we studied 60 eyes (60 patients) with increased intraocular pressure or glaucoma that had not responded to medical treatment, laser photocoagulation, or previous glaucoma surgery, in which the Ahmed Glaucoma Valve implant was placed to decrease intraocular pressure. RESULTS: Success was defined as intraocular pressure less than 22 mm Hg and greater than 4 mm Hg for two months or longer, intraocular pressure that was lowered by at least 20% from preoperative values (in eyes with preoperative intraocular pressures less than 22 mm Hg), and no additional glaucoma surgery or visually devastating complications. Cumulative probability of success at 12 months was 78%. Eight (13%) of 60 eyes had intraocular pressure less than 5 mm Hg the first postoperative day, Two other eyes had shallow anterior chambers, which required anterior chamber reformation. The major complications associated with the use of the valve were serous choroidal detachments in 13 eyes (22%), blockage of the tube in six eyes (10%), malposition of the tube in four eyes (7%), a suprachoroidal hemorrhage in one eye (2%), and corneal graft rejections in three (19%) of 16 eyes with corneal grafts. CONCLUSIONS: Although the 12-month success with the Ahmed Glaucoma Valve implant is similar to that reported for other drainage devices, the complications associated with overfiltration in the immediate postoperative period appear to be less frequent than with other valved drainage devices, Randomized, prospective studies to compare the Ahmed Glaucoma Valve implant with other drainage devices are needed to make clinical comparisons of the different devices.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [31] Intracorneal Hematoma After Ahmed Glaucoma Valve Implant Surgery
    Al Habash, Ahmed
    Al Abdulsalam, Omar
    Al-Qarni, Awad
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (09) : E202 - E204
  • [32] Safety and Efficacy of Second Ahmed Valve Implant in Refractory Glaucoma
    Posarelli, Chiara
    Toro, Mario Damiano
    Rejdak, Robert
    Zarnowski, Tomasz
    Pozarowska, Dorota
    Longo, Antonio
    Miccoli, Mario
    Nardi, Marco
    Figus, Michele
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 12
  • [33] Pyogenic Granuloma Formation Following Ahmed Valve Glaucoma Implant
    Chendran, Prema
    Fai, Tang Seng
    Halim, Wan H. Wan Abdul
    Din, Norshamsiah Md.
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (10) : E162 - E164
  • [34] Delayed Endophthalmitis in a child following an Ahmed glaucoma valve implant
    Al-Torbaq, AA
    Edward, DP
    [J]. JOURNAL OF AAPOS, 2002, 6 (02): : 123 - 125
  • [35] Efficacy of Ologen matrix implant in Ahmed Glaucoma Valve Implantation
    Marina Sastre-Ibáñez
    Carmen Cabarga
    María Isabel Canut
    Francisco Pérez-Bartolomé
    J. L. Urcelay-Segura
    R. Cordero-Ros
    Julián García-Feijóo
    Jose María Martínez-de-la-Casa
    [J]. Scientific Reports, 9
  • [36] The Ahmed Glaucoma Valve - a new implant for high intraocular pressure
    Hille, K
    Ruprecht, KW
    [J]. OPHTHALMOLOGE, 1999, 96 (10): : 653 - 657
  • [37] Outcomes of Ahmed Valve Implant Following A Failed Initial Trabeculotomy and Trabeculectomy in Refractory Primary Congenital Glaucoma
    Dave, Paaraj
    Senthil, Sirisha
    Choudhari, Nikhil
    Sekhar, Garudadri Chandra
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2015, 22 (01) : 64 - 68
  • [38] Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma
    Pakravan, Mohammad
    Esfandiari, Hamed
    Yazdani, Shahin
    Doozandeh, Azadeh
    Dastborhan, Zahra
    Gerami, Ebrahim
    Kheiri, Bahareh
    Pakravan, Parastou
    Yaseri, Mehdi
    Hassanpour, Kiana
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (01) : 44 - 51
  • [39] CLINICAL-EXPERIENCE WITH AN ENDOBRONCHIAL IMPLANT
    MARSH, BR
    COLVIN, DP
    ZINREICH, ES
    JACKSON, JF
    LEE, DJ
    [J]. RADIOLOGY, 1993, 189 (01) : 147 - 150
  • [40] Initial clinical experience with the Baerveldt BioSeal glaucoma implant.
    Ong, T
    Harasymowycz, P
    Katz, LJ
    Myers, JS
    Spaeth, GL
    Moster, M
    Steinmann, W
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S820 - S820