Real-time brachytherapy for prostate cancer - implant analysis

被引:5
|
作者
Szlag, Marta [1 ]
Slosarek, Krzysztof [1 ]
Rembielak, Agate [2 ]
Bialas, Brygida [2 ]
Fijalkowski, Marek [2 ]
Bystrzycka, Joanna [1 ]
机构
[1] Maria Sklodowska Curie Mem Ctr Oncol Inst, Dept Treatment Planning, Gliwice Branch, Gliwice, Poland
[2] Maria Sklodowska Curie Mem Ctr Oncol Inst, Dept Brachytherapy, Gliwice Branch, Gliwice, Poland
关键词
real-time brachytherapy; interstitial implant; prostate volume;
D O I
10.1016/S1507-1367(10)60076-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background In HDR brachytherapy precision of catheter implantation is crucial for conformal treatment planning as a starting point for better optimization process. Aim The aim was to investigate differences between virtual and real needle position and the effect of needle displacement on dosimetric parameters as a function of prostate volume for better evaluation of "real" implant with respect to final dose distribution. Materials/Methods Thirty treatment plans calculated by Nucletron SWIFT (TM) were randomly selected. Dosimetric data including V100 for prostate gland and D10 for urethra were analyzed as a function of prostate volume and needle displacement. Needle displacement was determined by measuring the distance between virtual and real positions of respective needles in three sectional images: at the base, apex of the prostate gland and reference image. Dosimetric parameters were determined for consecutive computer plans: virtual (before implantation), live (after implantation and renewed optimization). For the purpose of this study a new parameter, VD (Volume-Dose), was created. Results VD indicates the quality of "real" dose distribution with respect to "virtual" treatment plan. In order to realize the assumption of virtual plan (VD<1) for a given prostate volume, mean values of needle displacement r should not exceed r(acceptable) according to the formula: r(acceptable) (V-p) proportional to Vp(2). For larger glands (above 30cc) final dose distribution is less dependent on needle displacement than smaller ones. Conclusions The experiment determined maximum values of needle displacement for a given Vp parameter, allowing one to take advantage of optimization algorithms and to improve the final dose distribution.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 50 条
  • [41] Real-time segmentation of trans-urethral ultrasound images for prostate brachytherapy
    Holmes, DR
    Robb, RA
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 983 - 984
  • [42] Poor predictive value of intraoperative real-time dosimetry for prostate seed brachytherapy
    Igidbashian, Levon
    Donath, David
    Carrier, Jean-Francois
    Lassalle, Stephanie
    Hervieux, Yannick
    David, Sandrine
    Bahary, Jean-Paul
    Taussky, Daniel
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (02): : 605 - 609
  • [43] Permanent seed implant brachytherapy in low-risk prostate cancer: Preoperative planning with 145 Gy versus real-time intraoperative planning with 160 Gy
    Pons-Llanas, Olga
    Roldan-Ortega, Susana
    Celada-Alvarez, Francisco
    Jose Perez-Calatayud, Maria
    Fornes-Ferrer, Victoria
    Tormo-Mico, Alejandro
    Perez-Calatayud, Jose
    Luis Lopez-Torrecilla, Jose
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (04) : 290 - 297
  • [44] Adaptive and Real-time Approaches in Brachytherapy
    Hellebust, T. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S289 - S289
  • [45] Real-time dosimetry for HDR brachytherapy
    Moutinho, L.
    Castro, I. F. C.
    Freitas, H.
    Silva, K. A.
    Rachinhas, P. J.
    Simoes, P. C. P. S.
    Veloso, J. F. C. A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S945 - S945
  • [46] Sexual function after permanent implant brachytherapy for prostate cancer:: a multivariate analysis
    Chauveinc, L
    Flam, T
    Thiounn, N
    Solignac, S
    Timbert, M
    Rosenwald, J
    Nebout, N
    Firmin, F
    Debré, B
    Cosset, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S56 - S57
  • [47] REAL-TIME ELASTOGRAPHY IN THE DIAGNOSTIC EVALUATION OF PROSTATE CANCER
    Pelzer, Alexandre E.
    Hennenlotter, Joerg
    Schilling, David A.
    vonWeyhem, Claus H.
    Stenzl, Arnulf
    [J]. JOURNAL OF UROLOGY, 2009, 181 (04): : 782 - 782
  • [48] Prostate cancer diagnosis: value of real-time elastography
    Pallwein, Leo
    Aigner, Fritz
    Faschingbauer, Ralph
    Pallwein, Eva
    Pinggera, Germar
    Bartsch, Georg
    Schaefer, Georg
    Struve, Peter
    Frauscher, Ferdinand
    [J]. ABDOMINAL IMAGING, 2008, 33 (06): : 729 - 735
  • [49] The value of real-time elastography in the diagnosis of prostate cancer
    Salomon, G.
    Graefen, M.
    Heinzer, H.
    Huland, H.
    Pallwein, L.
    Aigner, F.
    Frauscher, F.
    [J]. UROLOGE, 2009, 48 (06): : 628 - 636
  • [50] Prostate cancer diagnosis: value of real-time elastography
    Leo Pallwein
    Fritz Aigner
    Ralph Faschingbauer
    Eva Pallwein
    Germar Pinggera
    Georg Bartsch
    Georg Schaefer
    Peter Struve
    Ferdinand Frauscher
    [J]. Abdominal Imaging, 2008, 33 : 729 - 735