USE OF A LARGE AREA PHOTODIODE IN CSI(TL) SCINTILLATION-COUNTERS

被引:20
|
作者
GUNJI, S
HANADA, N
HOSHINO, T
KAMAE, T
MIYAZAKI, S
TAKAHASHI, T
TAMURA, T
TANAKA, M
YAMAGAMI, T
MURAKAMI, H
MORI, K
TANAKA, H
YAMAMOTO, K
机构
[1] INST SPACE & ASTRONAUT SCI,SAGAMIHARA 229,JAPAN
[2] RIKKYO UNIV,DEPT PHYS,TOSHIMA KU,TOKYO 171,JAPAN
[3] CLEAR PULSE KK,OHTA KU,TOKYO 143,JAPAN
[4] HAMAMATSU PHOTON KK,DIV SOLID STATE,HAMAMATSU 435,JAPAN
关键词
D O I
10.1016/0168-9002(90)90719-M
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A newly developed large area photodiode has been studied as the photon sensor for medium-size CsI(Tl) scintillation counters. The photodiode has a sensitive area of 18 × 18 mm2 and a thickness of 500 μm. When combined with a CsI(Tl) crystal of 2.5 × 2.5 × 5.0 cm3, it gives an energy resolution of around 5.1% (FWHM) for 1.33 MeV gamma-rays. Characteristics of the low noise preamplifier designed for the CsI(Tl)-photodiode counter will also be given. © 1990.
引用
收藏
页码:400 / 404
页数:5
相关论文
共 50 条
  • [1] Use of a large area photodiode in CsI(T1) scintillation counters
    Gunji, S.
    Hanada, N.
    Hoshino, T.
    Kamae, T.
    Miyazaki, S.
    Takahashi, T.
    Tamura, T.
    Tanaka, M.
    Yamagami, T.
    Murakami, H.
    Mori, K.
    Tanaka, H.
    Yamamoto, K.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990, A295 (03):
  • [2] ENERGY RESOLUTION OF CSI(T1) SCINTILLATION-COUNTERS WITH PHOTODIODE-READOUT
    BIELER, C
    KRUGER, S
    STOCK, V
    STROHBUSCH, U
    HELVETICA PHYSICA ACTA, 1987, 60 (5-6): : 685 - 685
  • [3] VERY LARGE AREA SCINTILLATION-COUNTERS FOR HADRON CALORIMETRY
    BARISH, B
    BODEK, A
    CHU, YK
    KLEINKNECHT, K
    LEE, J
    LINSAY, PS
    LUDWIG, J
    SCIULLI, F
    SHAEVITZ, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 532 - 536
  • [4] CALIBRATION OF LARGE AREA SCINTILLATION-COUNTERS ON COSMIC-RAYS
    SATERLIE, SF
    TOMPKINS, DR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (07): : 857 - 862
  • [5] TIME COMPENSATOR FOR LARGE SCINTILLATION-COUNTERS
    FAUST, J
    LARSEN, RS
    NUCLEAR INSTRUMENTS & METHODS, 1974, 116 (02): : 365 - 368
  • [6] PARAMETERS OF VARIOUS TYPES OF LIGHT GUIDES FOR LARGE AREA SCINTILLATION-COUNTERS
    CHI, PC
    HONG, WZ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (01): : 67 - 74
  • [7] TIMING WITH SCINTILLATION-COUNTERS
    ELWAHAB, MA
    BATTRAWI, MH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 625 - 629
  • [8] Environmental monitoring using large-volume CsI(Tl) scintillation counters
    Ignatov, SM
    Chirkin, VM
    Potapov, VN
    Ivanov, OP
    Stepanov, VE
    Meng, LJ
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 380 - 384
  • [9] NEW CONCEPTS FOR THE DESIGN OF LARGE-AREA GAS PROPORTIONAL SCINTILLATION-COUNTERS
    CONDE, CAN
    DOSSANTOS, JMF
    BENTO, ACSSM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 452 - 454
  • [10] TIME-REFERENCING DEVICE FOR LARGE SCINTILLATION-COUNTERS
    BOREIKO, VF
    GREBENYUK, VM
    ZINOV, VG
    IVANOV, VV
    KOZHEVNIKOV, YA
    STOLETOV, GD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (05) : 1109 - 1112